www.sstcomm.com
23
5 IP Address Report
This feature allows GS11-MT periodically sending the IP address report to the user's IP address.
Open configuration software, search GS11-MT, and then open the configuration or the advanced configuration.
And open IP Address Report, as shown below:
Select “Enable”, enter the IP address and port number of terminal (Eg: computer) which receives reports.
NOTE: The terminal must be GS11-MT's IP address in the same network segment!
Fill in “Auto Report Period”. Download to GS11-MT and restart to use the function.
The following table is the packet format of IP Address Report.
Index
High Byte
Low Byte
0
“Sibo”
1
“Tech”
2
Length of Data
3
Product model, Example:“GS11-MT”
4
5
6
7
Serial Number