In this menu, you can create the
Access video panel (AVP) and/or
configure a recognised AVP. The
AVP is an indoor station with touch
screen, audio, video and control
functionality. The AVP has a flat
surface mount housing for wall and
table-top mounting. For table-top
mounting, you need a table-top
accessory.
Button configuration
Up to 44 tiles can be configured.
The designation and the symbols
for the tiles must be configured.
The designation can be individually
assigned. 26 different symbols (e.g.
light, group call) are available for
selection. If no symbol is selected,
one is automatically stored when it
is saved.
Remarks
• The inscription as well as the
selected symbol for a tile have
no
influence on the assigned function.
This means that you can assign a
function which does not match the
inscription or symbol to an inscribed
or symbolized tile (e.g. tile with
notification system
symbol with
the assigned function
Group call
).
• If other parameters have to be
configured for a particular button
assignment (e.g. with one switching
point), the
Set
button becomes
active.
After clicking on
Set
, a dialogue
is displayed in which the relevant
required data can be selected or
entered.
• The devices or users to which calls
can be rerouted depends on the log
-
ical grouping in the user tree and the
relevant user rights settings.
• Using
Scripts and switching
functions > Switching point
, the
Doormatic function can be assigned
to one of the buttons – provided
the Doormatic function is activated
for the user to which the device
assigned.
Procedure –
Configuring call
rerouting to any optional tile
1
In the
Button configura
-
tion
area, define the rerouting to
the required selection (device, user,
group, external) for one of the tiles.
2
Depending on the selection
(device, user, group, external), select
the destination to which all calls
should be rerouted.
3
Click on
Setting
.
4
In the
Parameterization
dia
-
logue, select:
• The time in seconds after which
you wish the waiting call to be
rerouted (if you define a time of e.g.
5 seconds, you can still accept the
call in this time).
• the routing source, i.e. a user or
group for which you want to set the
rerouting (depending on your rights).
5
Click on
Save
to save your selec
-
tion.
6
Click on
Save
to take the changes
over in the system.
7
Carry out a function test.
Switching outputs/inputs
Every Access video panel is equipped
with one switching input and one
switching output. The AVP can be
extended to include an additional
switching output/input using the
Access input/output accessory AZIO
870-…
Remarks
• The designation of the switching
output/input is displayed in the
switching lists of the Access termi
-
nals and in the button configuration
area on the administration interface.
You should consequently choose
meaningful designations.
• The function
Free switching
time
can additionally be statically
switched (
Toggle 0s
).
• Before you can assign a group
to the storey call, a group must be
configured.
• If other parameters have to be
configured for a particular tile
assignment (e.g. with one switching
point), the button
Setting
becomes
active.
• After clicking on
Setting
, a dia
-
logue is displayed in which the rel
-
evant required data can be selected
or entered.
Procedure –
Tile configuration
with switching point
1
In the
Button configuration
area, select the function
scripts and
switching functions
for one of
the tiles.
2
Select
Switching point
.
3
The
Set
button is displayed.
4
Click on
Setting
.
5
In the
Setting
dialogue, select the
switching output (e.g. Mr. Maier:
Output 1).
6
Click on
Save
to save your selec
-
tion.
7
Click on
Save
to take the changes
over in the system.