124
Configuring the door station
(ATLC)
In this menu, you can create a door/
door station and/or configure a rec
-
ognized door/door station. A door
station is always assigned directly to
a folder or a sub-folder.
Remarks
• The door loudspeaker controller
(ATLC) of the door station must be
restarted after initial installation or in
the event of changes (e.g. extension
to include call button modules).
After a successful restart, the con
-
figuration page of the ATLC must be
called up again so that the changes
made are displayed in the browser.
• During run-up, the Access door
loudspeaker controller of the door
station logs the connected modules
and if applicable the door camera
into the system.
Tip:
If you replace this Access door
loudspeaker controller, for instance
due to a service, then save the new
MAC address in this screen before
carrying out the replacement. This
means that the previous ATLC is
replaced by the new ATLC with the
existing configuration and there is
no need to carry out a new config
-
uration.
Procedure – Restart of the Access
door loudspeaker controller
1
In the
Users
menu, click on the
door/door station you wish to
reboot.
2
The page
Edit user: [door name]
opens in the content area.
3
Click in the header area onto
Restart
.
4
Confirm the confirmation prompt
to reboot with
Yes
.
5
In the event of a visible hardware
change, the displayed picture of
the door station is adjusted by the
Access server.
Button configuration
In the
Button configuration
area,
assign the individual buttons of the
door station to an executive func
-
tion. The number of configurable
buttons depends on the connected
call button modules.
Note
• If other parameters have to be
configured stored for a particular
button assignment (e.g. with one
switching point), the button
Setting
becomes active. After clicking on
Setting
, a dialogue is displayed in
which the relevant required data can
be selected or entered.
Procedure –
Button configuration
with switching point
1
In the
Users
menu, click on the
door/door station you wish to con
-
figure.
2
The page
Edit user: [door name]
opens in the content area.
3
In the
Button configuration
area, click on a
button
(e.g. button
1).
4
In the drop-down menu of the
selected button, select the function
Scripts and switching functions
.
5
A drop-down menu opens up.
6
Select the required function (e.g.
Switching point
).
7
The
Setting
button becomes
active.
8
Click on
Setting
.
9
In the
Setting
dialogue, select the
switching output (e.g. Mr. Maier:
Output 1).
10
Click on
Save
to adopt the
selected switching point.
Switching outputs/inputs
At
output 23,24
a door release,
an interfacing relay with equivalent
consumption or similar consumers
can be directly connected. The
output 23,24
is
not
a potential-free
switching contact but, independently
of its configuration,
a voltage emit
-
ting terminal
, to which no other
external voltages may be connected
or can be switched.
The remaining switching outputs can
be freely used, paying due attention
to the admissible electrical load
data, as potential-free configurable
switching outputs for wide-ranging
functions. Due to the use of poten
-
tial-free signalling contacts, the
switching inputs can be used for
wide-ranging functions.
Configure devices
ATLC 670-…