background image

 

 

 3

1.  About this document

1.1  Function

This operating instructions manual provides all the information you need for the mounting, 
set-up and commissioning to ensure the safe operation and disassembly of the safety swit-
chgear. The operating instructions must be available in a legible condition and a complete 
version in the vicinity of the device.

1.2  Safety instructions for authorised qualified personnel

All operations described in this operating instructions manual must be carried out by trained 
specialist personnel, authorised by the plant operator only. Please make sure that you have 
read and understood these operating instructions and that you know all applicable legisla-
tions regarding occupational safety and accident prevention prior to installation and putting 
the component into operation. The machine builder must carefully select the harmonised 
standards to be complied with as well as other technical specifi cations for the selection, 
mounting and integration of the components.

1.3  Symbols

Caution

Failure to comply with this warning notice could lead to physical injury and/or 
damage to the machine.

Information

Hilfreiche Zusatzinformationen

1.4  Appropriate use

The products described in these operating instructions are developed to execute safety-related 
functions as part of an entire plant or machine. It is the responsibility of the manufacturer 
of a machine or plant to ensure the correct functionality of the entire machinery or plant.
The safety switchgear must be exclusively used in accordance with the versions listed below 
or for the applications authorised by the manufacturer. Detailed information regarding the 
range of applications can be found in the chapter „2. Product description“.

1.5  General safety instructions

The user must observe the safety instructions in this operating instructions manual, labelled 
with the caution or warning symbol above, the country-specifi c installation standards as 
well as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the SSP catalogues or in the 
online catalogue on the Internet: www.safety-products.de.

The information contained in this operating instructions manual is provided without liability 
and is subject to technical modifi cations.
There are no residual risks, provided that the safety instructions as well as the instructions 
regarding mounting, commissioning, operation and maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of the safety switchgear, 
personal hazards or damages to machinery or plant components cannot be 
excluded. The relevant requirements of the standard 
ISO 14119 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from defective mounting 
or failure to comply with this operating instructions manual. The manufacturer shall accept 
no liability for damages resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary repairs, conversions 
and modifi cations to the device are strictly forbidden; the manufacturer shall accept no 
liability for damages resulting from such invasive work, arbitrary repairs, conversions and/
or modifi cations to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

Type code SAFIX 

➀ ➁

 Coding variations

 

Standard coding

 

Individual coding

 

Individual coding, re-teachable

Transmitter (actuator)

 Option

Diagnostic output

Standard actuator

Flacher actuator

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, these specifi cations 
apply accordingly, provided that they correspond to the standard version.

2.3  Destination and use

This non-contact, electronic safety switch is designed for application in safety circuits and 
is used for monitoring the position of movable safety guards. In this application, the safety 
switch monitors the position of hinged, sliding or removable safety guards by means of 
the coded electronic actuator.
The safety function consists of safely switching off the safety outputs when the safety guard 
is opened and maintaining the safe switched off condition of the safety outputs for as long 
as the safety guard is open.

2.4  Series connection

Series connection can be set up. The response and risk times are not altered by wiring in 
series. The number of components is only limited by the external cable protection according 
to the technical data and the line loss.
Protection is not required when pilot wires are laid. The cables however must be separated 
from the supply and energy cables. The max. fuse rate for a sensor chain depends on the 
section of the connecting cable of the sensor.

The entire concept of the control system, in which the safety component is 
integrated, must be validated to the relevant standards.

2.5  Technical data

Standards: 

IEC 60947-5-3, IEC 61508, ISO 13849-1

Enclosure: 

Thermoplastic hotmelt

Operating principle: 

RFID

Frequency band: 

125 kHz

Transmission power: 

max. -6 dBm

Actuator: 

SAFIX T3

Series connections: 

Unlimited number of components,

 

lease observe external cable protection 

Connection: 

Connector plug M8, 8-pole, A-coded

Switching distances according to IEC 60947-5-3

Typical switching distance: 

12 mm; 

- lateral actuation: 

9 mm

assured switching distance S

ao

10 mm;

- lateral actuation: 

6 mm

assured swtiching distance S

ar

18 mm;

- lateral actuation: 

15 mm

Hysteresis: 

< 2,0 mm

Repeat accuracy R: 

< 0,5 mm

Ambient conditions

Ambient temperature Tu: 

−25 °C … +65 °C 

Storage and transprot temperature: 

−25 °C … +85 °C

Protection class: 

IP65 / IP67 to IEC 60529

Resistance to vibration: 

10 … 55 Hz, Amplitude 1 mm

Resistance to shock: 

30 g / 11 ms

Switching frequency f: 

1 Hz

Drop-out time: 
- Actuator 

≤ 100 ms

Duration of risk: 

≤ 200 ms

Time to readiness: 

≤ 2 s

Electrical data

Rated operating voltage Ue: 

24 VDC −15% / +10%

 

(PELV to IEC 60204-1)

Rated operating current Ie: 

0,6 A

Minimum operating current Im: 

0,5 mA

Required rated short-circuit current: 

100 A

Rated insulation voltage Ui: 

32 V

Rated impulse withstand voltage Uimp: 

800 V

No-load current Io: 

35 mA

Overvoltage category: 

III

Degree of pollution: 

3

Safety inputs X1/X2

Rated operating voltage Ue1: 

24 VDC −15% / +10%

 

(PELV unit)

Power consumption per input: 

5 mA

Safety outputs Y1/Y2 

p-type, short-circuit proof

Operating current Ie1: 

max. 0,25 A

Utilisation category: 

DC-12: Ue/Ie: 24 VDC / 0,25 A; 

 

DC-13: Ue/Ie: 24 VDC / 0,25 A

Voltage drop: 

Ue < 1 V

Diagnostic output 

p-type, short-circuit proof

Operating current Ie2: 

max. 0,05 A

Utilisation category: 

DC-12: Ue/Ie: 24 VDC / 0,05 A; 

 

DC-13: Ue/Ie: 24 VDC / 0,05 A

Voltage drop: 

Ue < 2 V

Operating current: 

150 mA

Wiring capacitance: 

max. 50 nF

Device fuse rating: 

≤ 2 A bei Einsatz gemäß UL 508

2.6  Safety classification

Standards: 

EN ISO 13849-1, IEC 61508, IEC 62061

PL: e
Category: 4
PFH value: 

6,8 x 10

-10

 / h

PFD: 

1,2 x 10

-4

SIL: 

suitable for SIL 3 applications

Service life: 

20 years

2.7  Forseeable defeat according to ISO 14119

SAFIX S 

low coding level

SAFIX I 

high coding level

SAFIX W 

high coding level

3.  Mounting

3.1  General mounting instructions

During fi tting, the requirements of ISO 14119 must be observed.

The mounting holes provide for a variable mounting by means of M4 screws (max. tightening 
torque 0.8 Nm). The component can be mounted in any position. The labelled surfaces of 
the safety switch and the actuator have to be opposite. The safety switch must only be used 
within the assured switching distances ≤ 

sao

 and ≥ 

sar

.

Safety switch and actuator must be permanently fitted to the safety guards 
and protected against displacement by suitable measures (tamperproof screws, 
gluing, drilling of the screw heads). 

The mounting holes provide for a variable mounting by means of M4 screws (max. tightening 
torque 0.8 Nm). The component can be mounted in any position. The labelled surfaces of 
the safety switch and the actuator have to be opposite. The safety switch must only be used 
within the assured switching distanTo avoid any interference inherent to this kind of system 
and any reduction of the switching distances, please observe the following guidelines:
•  The presence of metal chips in the vicinity of the sensor is liable to modify the switching 

distance.

•  Keep away from metal chips.
•  Minimum distance between two sensors: 100 mmes ≤ 

sao

 and ≥ 

sar

.

Wrong Right

100 mm

Reviews: