background image

mini LITE 

USER MANUAL 

Summary of Contents for miniLITE SS348

Page 1: ...miniLITE USER MANUAL ...

Page 2: ...1 PRODUCT SPECIFICATIONS 1 1 TECHNICAL SPECIFICATIONS LED MODULE VOLTAGE 18 5VDC POWER 20W IP RATING IP 65 OPERATION TEMPERATURE 0 C 40 C DIMENSIONS 143X105X190mm 1Kg 1 2 SIZE CHART 1 104 9 ...

Page 3: ...m must be maintained between the equipment and combustible surface The product must always be placed in a well ventilated area Always make sure that the equipment is installed securely DO NOT stand close to the equipment and stare directly into the LED light source Always disconnect the power supply before attempting maintenance Always make sure that the supporting structure is solid and can suppo...

Page 4: ...eiver card is already paired with a WDMX transmitter then the fixture is ready for receiving OMX signal If the WDMX receiver card needs to be paired with a new WDMX transmitter select YES from the WDMX REST menu The green signal indicator LED will not show which confirms that WDMX receiver card is unpaired and ready for new pairing o 6 4 By pressing the RESET button on W DMX transmitter transmitte...

Page 5: ...to play required play function see section 2 3 3 forfurtherinformationon how to patch EFFECTKEY Select SPEED or SPEED to adjust speed play function It is not possible to adjust the light level of the EFFECTprograms using the DIMMER keys 5 4 DIMMER There is a bottom for all color RGBWACU dimmer lower right corner is a on off bottom for fixture on off operation 15 3 DISPLAY PANEL OPERATION 3 1 DISPL...

Page 6: ...t the DMXADDRESS 5 CHANNEL 17 18 19 20 VALUE FUNCTION SPECIAL STROBE 0 9 NO FUNCTION 10 50 STROBE FROM CSLOD TO FAST 0 25Hz 5 1 100 NO FUNCTION 101 150 LIGHTNING STROBE 15 1 200 NO FUNCTION 201 255 RANDOM SROBE AUTO 0 40 NO FUNCTION 4 1 50 ATU01 5 1 60 ATU02 51 10 ATU03 7 1 80 ATU04 8 1 90 ATU05 9 1 100 ATU06 101 110 ATU07 111 120 ATUOB 1 2 1 130 ATU09 131 140 ATU010 141 150 PROGRAM1 15 1 160 PROG...

Page 7: ...N 0 BLUE DOWN RED 100 GREEN UP BLUE UP RED DOWN GREEN DOWN BLUE 100 ALL LEDAT FULL OUTPUT 2700K 3000K 3200K 3500K 4000K 4200K 4500K 5600K 6000K 6500K 7200K 8000K 13 3 5 ACTIVATINGAUTO PROGRAMS MENU AUTO CJ 0 255 R 10 e Select the target AUTO PROGRAM program and press ENTER Programs AUTO 01 to AUTO 10 are fully pre programmed and will not bealtered by changes in EDIT l mode Programs PR 01 to PR 10 ...

Page 8: ...der to save the last DMX data incase of DMX signal error Choose BLACK in order to blackout in case of DMX signal error 3 9 ACTIVATE THE PASSWORD MENU c K_EY_ l r o N OFF Enter the KEY mode to select whether the access password is on or off When the fixture is set as PASS ON after 30 seconds or turn on the fixture next time the fixture will need an accesspassword to enter the display menu control N...

Page 9: ...ation to enterthe correct password UP DOWN UP DOWN Key press the MENU l in the correct password will enter show submenu MENU CAUBRATION WHITE H 01 0 255 G 0 255 B 0 255 W 0 255 RGB to W IR 0 255 J IG 0 255 l B 0 255 J UC GREEN WHITE J AMBER UV Enter the CALIBRATION to select white color of different color temperature There are 12 pre programmed White colors can be edited by using RED GREEN BLUE WH...

Page 10: ...9 NO FUNCTION 10 so STROBE FROM SLOD TO FAST 0 25Hz 6 s1 100 NO FUNCTION 101 150 LIGHTNING STROBE 1s1 200 NO FUNCTION 201 2ss RANDOM SROBE DIMMER SPEED o 9 NO FUNCTION 10 29 OFF 7 30 69 DIM1 70 129 DIM2 130 189 DIM3 190 2ss DIM4 9 SSP CHANNEL VALUE FUNCTION 1 0 2ss MASTER DIMMER 2 0 2ss RED 3 0 2ss GREEN 4 0 2ss BLUE 5 0 2ss WHITE 6 0 2ss AMBER 7 0 2ss CYAN 8 0 2ss UV SPECIAL STROBE o 9 NO FUNCTIO...

Reviews: