    SETTING UP WITH A DMX512 CONTROLLER 

2.3-1  DMX512 ADDRESSING WITHOUT ID ADDRESSING
           

(

TOUR MODE)

The figure above shows a simple DMX512 
layout with the starting address of the first 
unit set at 1, with the second set at 11and 
so on...  (Note that when used in this way,
the Ch10 ID function must be  inactive (CH10=0))

DMX512
CONTROLLER

 Connect the DMX512 controller to the units in series.  
 Each unit has 10 DMX channels so the DMX Addresses should increase by

     increments of  10 (e.g. 1,11,21,31...)

The ID address has not been set so therefore when using the controller CH

   10 must  be inactive ( CH10=0 ).

It is also possible to deactivate ID address selecting

ID OFF

from the

  

Settings

menu. on the fixture 

 Each DMX Address may be used as many times as required.
 Any DMX address in the range from 001 to 512 may be used.

2.3-2  DMX512 ADDRESSING WITH ID ADDRESS
          (TOUR MODE)

 Connect the DMX512 controller to the units in series
 Each unit has 10 DMX channels so the DMX Addresses should increase by

     increments of  10 (e.g. 1,11,21,31...)

 Each DMX Address may be used as many times as required.
 Any DMX address in the range from 001 to 512 may be used.
 Each DMX address may carry up to 66 separate ID addresses.
 

ID

should be set in the menu on each unit in ascending values

    (i.e. 1,2,3...)

 

ID On

should be set in the

Settings

menu on each unit.

 ID addresses are accessible from Ch10 on the DMX512 controller.

Example:

............

DMX Addr.1

DMX Addr.11

DMX Addr.21

ID ADDRESS

ID1~ID66

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

 9

10 

 19

20 

 29

30 

 39

40 

 49

50 

 59

60 

 69

70 

 79

80 

 89

1~20Hz

STROBE

5

NO FUNCTION

WARM WHITE

COOL WHITE

CHANNEL   

FUNCTION

VALUE  

6

WHITE MACROS

 9

NO FUNCTION

ID11

ID12

ID13

110 

 119

120 

 129

130 

 139

ID14

ID15

140 

 149

150 

 159

ID21

210

ID66

255

ID20

200 

 209

ID18

ID16

ID17

160 

 169

170 

 179

180

 189

ID19

190 

 199

ID9

ID10

90 

 99

100 

 109

Summary of Contents for CAM/TZ YG-LED318

Page 1: ...USER MANUAL YG LED318 CAM TZ CAM TZ...

Page 2: ...CONTROLLER 3 2 3 1 DMX512 ADDRESSING WITHOUT ID ADDRESSING 4 2 3 2 DMX512 ADDRESSING WITH ID ADDRESS 4 2 2 POWER CONNECTION 3 3 3 EDIT STATIC COLOUR 9 PART 5 APPENDIX 25 5 1 MAINTENANCE 25 3 5 RUN MO...

Page 3: ...mum COOL WHITE WARM WHITE SELECTION CH2 and CH3 control the intensity ratio of each of the WARM WHITE COOL WHITE LEDs When the slider is at the highest position 255 the intensity of the color is the m...

Page 4: ...al packaging in which the product left the factory Shields lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired The lamp LE...

Page 5: ...able should also be used 220V 24 units may be connected in series 120V 12 units may be connected in series The LED MODULE can be mounted at any angle and in any position It is possible to further adju...

Page 6: ...used 2 3 2 DMX512 ADDRESSING WITH ID ADDRESS TOUR MODE Connect the DMX512 controller to the units in series Each unit has 10 DMX channels so the DMX Addresses should increase by increments of 10 e g...

Page 7: ...MX address and then by using Ch10 to locate the target ID address DMX Addr 1 ID Addr 1 DMX Addr 1 ID Addr 2 DMX Addr 1 ID Addr 3 DMX Addr 12 ID Addr 1 DMX Addr 12 ID Addr 2 DMX Addr 12 ID Addr 3 Note...

Page 8: ...ue of thecurrent function scroll DOWN through the menu list or decrease the value of the current function scroll through the main menu or return to the main menu MENU ENTER Ar2 s 1 2 0 255 CHANNEL FUN...

Page 9: ...0 20 STAT PERS EDIT HSV KEY ON OFF WT01 WT02 WT11 Red Green Blue White 0 255 0 255 0 255 0 255 CAL1 RGBW Red Green Blue 0 255 0 255 0 255 CAL2 SET UPLD ID ON OFF REST RGBW COLOR Dim1 Dim3 Dim2 Dim4 Di...

Page 10: ...dIM3 dIM2 dIM4 dIM OFF W 0 255 C 0 255 UNO ID21 ID22 210 211 11 ID20 200 209 ID19 190 199 ID18 180 189 ID14 ID15 ID16 ID17 140 149 150 159 160 169 170 179 ID65 ID66 254 255 ID8 ID9 ID10 ID11 ID12 ID13...

Page 11: ...M 8 CUSTOM 9 CUSTOM 10 121 130 131 140 141 150 151 160 161 170 171 180 181 190 191 200 201 210 CUSTOM 1 211 220 221 255 71 80 81 90 91 100 101 110 AUTO 6 AUTO 7 AUTO 8 AUTO 9 111 120 AUTO 10 0 20 21 3...

Page 12: ...ION VALUE BLUE WHITE GREEN or FADE TIME when CUS 01 CUS 10 in CH8 is activated RED or STEP TIME when CUS 01 CUS 10 in CH8 is activated MASTER DIMMER 6 WHITE1 3200K WHITE2 3400K WHITE3 4200K WHITE4 490...

Page 13: ...turn on the fixture next time the fixture will need an access password to enter the display menu control Note The factory access password is UP DOWN UP DOWN then press ENTER to confirm the access WT01...

Page 14: ...he MASTER and SLAVEunits will display GREEN In order to reset custom modes to default values select REST Enter ID in order to allow disallow ID address function from the DMX512 controller COLOR is for...

Reviews: