background image

 

http://www.ce-transducer.com

                    3rd Floor, building 1, Zaimao industrial park, Baoji road, Bantian, Longgang district, 

[email protected]

                            Shenzhen City, China      Post code: 518049

Three-phase four-wire AC voltage transducer 

Istructions 

CE - VJ41 - *9MSK - 0.5 

1 Overview

 

This device is a 3-phase AC voltage isolation transducer. Using the 

principle  of  electromagnetic  isolation

 

to  measure  the  three-phase 

AC  voltage  signal,  isolate  and  linearly  output  a  variety  of 

selectable  standard  signals.  It  can  widely  used  in  AC  voltage 

signal  real-time  detection  and  monitoring,  communications, 

electricity, railways, industrial control and other fields. 

Features

 

Ø

 

Easy installation; 

Ø

 

High precision, low temperature drift; 

Ø

 

Three-phase voltage independent of each other; 

Ø

 

High reliability. 

 

2

 Case Style 

 

 

 

 

 

 

 

Figure 1, MSK outline 

 

3 Part Number 

 

4 Specifications

 

Test  conditions:  auxiliary  power:  220VAC,  room  temperature: 

25

°

C; 

Input Range: 0~600VAC; 

Output: 0~5VDC, 0~10VDC, 0~20mADC, 4~20mADC; 

Power supply: 85~265VAC/DC; 

Accuracy: 0.5; 

Load capacity: 

2K

Ω

 (voltage output), 

250

Ω

 (current output); 

Temperature drift: 

500ppm/

°

C

;

 

Isolation voltage: 

2500 VDC;   

Response time: 

300 mS; 

Rated  power  consumption:  1W  (voltage  output);  2W  (current 

output); 

Output ripple: 

10mV; 

Frequency  range:  (45~65Hz  up  to  5K,  please  specify  when 

ordering); 

Surge immunity: 

Power port level 

±

 0.5KV (L-N/2

Ω

/integrated wave)                                   

Analog I / O port.

±

 0.5KV (L-N/40

Ω

/ integrated wave) 

Impulse immunity: input / power port 

±

 2KV, analog I / O port 

±

 

1KV; 

Input overload capacity: Voltage: 2 times the nominal value;   

Operating temperature: -10 ~ 60

°

C; humidity: 

95 %( no dew); 

Storage temperature: -55 ~+65

°

C

;

 

humidity: 

95 % (no dew). 

5 Connections Diagram 

(For  reference  only,  the  actual  application  to  the  product  wiring 

diagram shall prevail) 

 

 

 

 

 

 

Figure 2, CE-VJ41-39MSK/CE-VJ41-89MSK voltage output, 

CE-VJ41-49MSK/CE-VJ41-59MSK 

current 

output

 

Product 

wiring diagram. 

6

 

Installations 

DIN35  rail  mounting  or  screw  mounting,  the  installation  size         

as shown in figure (in mm). 

 

 

 

 

 

 

 

Figure 3, SK outline installation dimensions 

7 Product

s Service

 

1 Installation 

1.1 DIN rail installation method: 

Fix

 

the transducer on the side of the card slot and hook on the 

mounting rail; 

Pull the spring pin down; 

Clip the transducer mount on the mounting rail; 

Phase-A 
Phase-B 
Phase-C 

Power Supply 

Phase-CA 
Phase-BC   
Phase-AB

 

Reviews: