All-in-one solar charge inverter V1.0 33
3.2
Output mode
1、Solar First:
PV and battery will power the load, with diversified charging modes available and
output mode optional, when the Solar First Mode is selected, the use of green solar energy can
be maximized for energy efficiency and emission reduction. Switch to Mains Power when PV has
failed. This mode can maximize the use of solar energy while maintaining the battery power,
which is suitable for regions with relatively stable power grid.
2、Mains First:
switch to inverter power supply only when Mains Power has failed, which is
equivalent to backup UPS and is used in regions with unstable power grid.
3、Inverter First:
switch to Mains Power supply only when the battery is under-voltage. This
mode uses DC energy to the maximum extent and is used in regions with stable power grid.
4、Hybrid output and gird connection(need to be abled)
In the utility bypass state, when no
battery is connected or when the battery is full, the load power is supplied by the PV and the
utility together if the hybrid function is enabled, and the surplus PV energy is fed back to the grid
if the grid connection function is enabled.