![Srne HF4830S60-H Product Manual Download Page 20](http://html1.mh-extra.com/html/srne/hf4830s60-h/hf4830s60-h_product-manual_1354150020.webp)
Real-time data view method
In LCD main screen, press keys “UP” and “DOWN” to turn page and view different realtime
data of the machine.
Page
Left Parameter of Screen
Middle
Parameter of
Screen
Right Parameter of Screen
1
Battery input voltage
Fault code
Output voltage
2
PV temperature
PV output KW
3
PV input voltage
PV output current
4
Input battery current
Output battery current
5
Input battery KW
Output battery KW
6
AC input f
7
AC input voltage
AC output load current
8
Input voltage
Output load KVA
9
INV temperature
INV output load KW
10
APP software version
Bootloader software version
11
Model Battery Voltage Rating
Model Output Power Rating
12
Model PV Voltage Rating
Model PV Current Rating
4.5 Setting parameter
Key operation description: to enter setting menu and exit from setting menu, please press key“SET”. After
entering the setting menu, parameter number
【
00
】
shall flash. At this time, press keys “ UP ” and “ DOWN ”
to select the parameter item code to be set. Afterwards, press key“ ENT” to enter parameter editing state. At
this moment, the parameter value can flash. The parameter values are adjusted through keys “UP” and
“DOWN”. In the end, press key“ENT” to complete parameter editing and return to parameter selection state.
Solar Energy Storage Inverting & Control All-In-One Machine 20