CLEANING and DISINFECTING 

CLEANING 

 

To clean the display / user interface and other scale contact areas: 

 

Use a soft cloth dampened with water and mild detergent to clean scale surfaces. 

 

Wipe surface with clean soft cloth dampened with water and then dry with clean soft cloth.  

 

Do  not  use  abrasive  materials  to  clean  scale  surface  to  prevent  damage  to  the  surface 
finish. 

 

Do not spray liquid directly onto scale surfaces.  Use only a damp cloth. 

 

DISINFECTION 

To disinfect the display / user interface and other scale contact areas:  

 

Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth. Cloth 

cannot  be  dripping  wet.  Follow  manufacturer’s  instruction  on  the  proper  use  of 
commercially available disinfectants. 

 

Disinfectant solutions with 1% sodium hypochlorite or 70% isopropyl alcohol are suitable 
for display / user interface and other scale contact surfaces. 

 

After  disinfecting,  use  a  soft  cloth  dampened  with  clean  water  and  dry  with  a  soft  clean 
cloth to prevent buildup of material on scale finish. 

 

Do  not  use  abrasive  material  to  disinfect  /  clean  scale  surfaces  to  prevent  damage  to  the 
surface finish. 

 

Do not spray liquid directly onto scale surfaces. Use only a damp cloth. 

 

WARNING:

 

DO  NOT  SPRAY  CLEANING  SOLUTION  OR  LIQUIDS  DIRECTLY 
ON SURFACES TO BE CLEANED

 

WARNING:  EXPOSURE  TO  EXCESSIVE  LIQUID  WILL  DAMAGE  USER 

INTERFACE KEYPAD. 

 

WARNING:

 

DO  NOT 

USE  PRESSURIZED  WATER  OR  STEAM.  THE  SCALE 

SYSTEM CONTAINS ELECTRONIC COMPONENTS THAT MAY BE 

ADVERSELY  AFFECTED  BY  EXPOSURE  TO  SUCH  AN 

ENVIRONMENT. 

Summary of Contents for SR735i

Page 1: ..._MICROBAN_201210 Page 1 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S...

Page 2: ...USE 6 MICROBAN ANTIMICROBIAL PROTECTION 6 STORAGE 6 CLEANING AND DISINFECTING 7 SPECIFICATIONS 8 BUTTON FUNCTIONS 9 BASIC SYSTEM OPERATION 11 BATTERY REPLACEMENT 12 THEORY OF OPERATION 13 CALIBRATION...

Page 3: ...wanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc PACKING CHECKLIST SR735i Platform Scale DESCRIPTION QUANTITY Box 1 WHE...

Page 4: ...lease call the service hotline at 1 800 654 6360 STEP 2 Verify that the serial number on the Display Unit matches that on the Wheelchair Scale Assembly STEP 3 The SR735i Display may be wall mounted Fi...

Page 5: ...ing Bracket Figure 4 Use the wall mounting hardware provided for installing the bracket STEP 2 Carefully attach the printer to the Printer Mounting Bracket Connect the printer cable from the printer t...

Page 6: ...be viewed either in pounds or kilograms with a displayed resolution of 0 1 for each INTENDED USE The SR735i Wheelchair Scale System is specifically designed for weighing both motorized wheelchair and...

Page 7: ...eas Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disin...

Page 8: ...e AUTO ZERO One button operation AUTO POWER DOWN Approximately 30 seconds adjustable to 300 seconds RECALL Recalls last stored stable weight height and BMI AVERAGING Automatic digital filter POWER SUP...

Page 9: ...when stable Auto stores stable weight in memory SEND PRINTER EHR Press to send stored values to EHR or to printer Output values include time date weight height and BMI Also indicated on display when...

Page 10: ...ON TIME Use UP or DOWN arrow buttons to adjust the ON TIME The ON TIME may be set from 30 to 300 seconds in 30 second increments Press ENTER to save changes Setting TIME and DATE Use the UP arrow butt...

Page 11: ...When the weight is stable the weight stable indicator remains solid The display will indicate the patient s weight in either pounds or kilograms example WT 123 5 Lb The stable weight is auto stored i...

Page 12: ...example RCL WT 123 5 Lb RCL HT 65 in and RCL BMI 20 5 BATTERY REPLACEMENT STEP 1 The display will read REPLACE BATTERY STEP 2 Figure 7 Unscrew the panel screw on the Battery Compartment Cover and remo...

Page 13: ...plifier is configured to current sum the output of each cell with potentiometers serving to normalize the sensitivity voltage out per unit of weight applied of each bridge The offset potentiometer pro...

Page 14: ...subset of weight that is less than half of the combined weight DO NOT USE barbells or uncalibrated weights STEP 2 Zero the scale by pressing and holding ZERO WEIGH button STEP 3 Place the subset of c...

Page 15: ...weight of the calibrated weights Use the UP arrow button to select the digit and the DOWN arrow button to change digit Press ENTER to save changes STEP 4 Press the MENU button until HALF 500 00 Lb is...

Page 16: ...EP 5 Switch the scale system out of the Calibration Mode on the display board Figure 9 STEP 6 Place the left end cover on the display housing Attach using three 3 cover screws EHR OUTPUT Electronic Me...

Page 17: ...ry Wait five seconds then re install the battery and try the WEIGH button again The display lights appear to work but do not respond to button activation Check to ensure the membrane switch label is c...

Page 18: ...abilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no...

Page 19: ...and Service Manual Part No MAN735i _MICROBAN_201210 Page 19 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments co...

Page 20: ...AN735i _MICROBAN_201210 Page 20 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstrument...

Reviews: