background image

Model SRV949-BT 24 X 60 Platform Scale App-Enabled 
Operating and Service Manual 
Part No.:  MAN949-BT_220429 

 

Page 7 of 16 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel:  716-693-5977     Fax:  716-693-5854    URL:  

www.srscales.com

 

email:  

[email protected]

        Copyright 2022

 

Instruments, Inc. 

 

SPECIFICATIONS 

 

MAXIMUM WEIGHT CAPACITY 

400 lb / 182 kg 

PLATFORM SIZE 

24 in x 60 in x 2 in 
(61 cm x 152 cm x 5 cm) 

DISPLAY TYPE 

1.0” LCD display with 5 active digits 

DISPLAY RESOLUTION 

0.2 lb / 0.1 kg 

ACCURACY 

0.2% +/- 2 digits of displayed resolution for calibrated 
range 

AUTO ZERO 

One button operation 

AUTO POWER DOWN  

Approximately 300 seconds 

AVERAGING 

Automatic digital filter 

POWER SUPPLY 

Six (6) AA 1.5 volt alkaline batteries 

CALIBRATION 

Calibration is traceable to NIST standards 

 

OPERATING CONDITIONS 

Normal operating conditions for this product: 
Ambient  Temperature  Range:  68

F  to  85

F  (20

C  to 

30

C),  Relative  Humidity  Range:  0%-85%.    Avoid 

exposure to high-pressure water or steam.

 

 

TRANSPORT and STORAGE 

Storage  and  transport  conditions  should  not  vary 
outside  the  following  conditions:    Relative  Humidity 
0% to 85%, Ambient Temperature 14

F to122

F (-10

to  +50

C).    Remove  batteries  if  storing  longer  than 

three (3) months. 

BLUETOOTH REQUIREMENTS 

Refer to 

the SR Scales App

 on the Google Play store 

for further information. 

 

Summary of Contents for SRScales SRV949-BT

Page 1: ...0429 Page 1 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2022 S Instruments Inc S by S Instru...

Page 2: ...4 SYSTEM DESCRIPTION AND INTENDED USE 5 STORAGE AND TRANSPORTATION 5 CLEANING AND DISINFECTING 6 SPECIFICATIONS 7 BUTTON FUNCTIONS 8 BASIC SYSTEM OPERATION 9 BATTERY REPLACEMENT 9 PAIRING TO BLUETOOT...

Page 3: ...Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2022 S Instruments Inc PACKING CHECKLIST Model SRV949 BT Portable Platform Scale...

Page 4: ...ments Inc ASSEMBLY To install included six 6 AA 1 5 volt alkaline batteries follow steps below STEP 1 Unlatch tab on the Battery Compartment cover on bottom of scale Figure 2 STEP 2 Insert batteries a...

Page 5: ...lograms The SRV949 BT Platform scale is equipped with a Bluetooth wireless module By waking the scale up with the WEIGH button the wireless feature is turned on Then use the free SR Scales app Google...

Page 6: ...on on the proper use of commercially available disinfectants Disinfectant solutions with 1 sodium hypochlorite or 70 isopropyl alcohol are suitable for display user interface and other scale contact s...

Page 7: ...ange AUTO ZERO One button operation AUTO POWER DOWN Approximately 300 seconds AVERAGING Automatic digital filter POWER SUPPLY Six 6 AA 1 5 volt alkaline batteries CALIBRATION Calibration is traceable...

Page 8: ...during this procedure The display will read 0 0 LB or KG The button also wakes up the display and shows the animal s weight if it should Auto Power Down before the weighing process is done HOLD RECAL...

Page 9: ...ing surface remains active If scale shuts down press the ZERO WEIGH button once to wake display and take reading HOLD RECALL The scale display is designed to automatically lock the reading on the disp...

Page 10: ...s listed on the Calibration Form 4 Select the appropriate device and select pair 5 Open the SR Scales application Press the three dots in the upper right hand corner Figure 4A and select Connect a dev...

Page 11: ...for remote wireless operation Use your Android device to display weight and control the SRV949 BT scale functions Figure 5 Ensure your remote display indicates CONNECTED before use The WEIGH button w...

Page 12: ...WEIGH button STEP 3 Place the first calibrated weight on the scale Wait for scale to stabilize note scale reading Remove weight STEP 4 Place second calibrated weight on scale Wait for scale to stabil...

Page 13: ...GH button to turn the scale on STEP 3 Press Lb Kg button and toggle to select lb STEP 4 Press the Calibration button on rear of display Display will read CAL STEP 5 Toggle the ZERO WEIGH button to rea...

Page 14: ...NUMBER STEP 11 When display reads SAVE press the HOLD RECALL button to cycle through Savd and return to CAL STEP 12 Calibration is completed Press the left button on rear of display to return to run...

Page 15: ...ns or liabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said article...

Page 16: ...nual Part No MAN949 BT_220429 Page 16 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2022 S Ins...

Reviews: