Model SR7020
i
Wall Mount Platform Scale
Operating and Service Manual
Part No.MAN7020I_MICROBAN_200520
Page 4 of 16
S
Instruments, Inc.
,
600 Young Street, Tonawanda, NY 14150
Tel: 716-693-5977 Fax: 716-693-5854 URL:
email:
S
Instruments, Inc.
38-3/4” from
floor
Outer Mounting
Holes are 16”
on Center
Inner Mounting
Holes
INSTALLATION (CON’T)
STEP 3:
To mount the SR7020
i
Wall Mount Platform Scale use the Wall Bracket (Figure 1) supplied with
the scale.
STEP 4:
When the desired location is determined, use a tape measure and measure up from the floor 38 ¾”
and make a mark. This will be the location of top edge of the wall mounting bracket (Figure 2).
NOTE
: The wall mounting bracket does not need to be centered on the crossbar, but must be located
between the bumpers
STEP 5:
For stud walls, use a stud finder and locate any studs in the mounting area:
• For two (2) studs located within the mounting area (usually 16” on center) align the outer mounting
holes with the studs, level the wall bracket and mark all four screw locations.
• For one (1) stud located within the mounting area align the inner mounting holes with the stud,
level the wall bracket and mark all four screw locations.
• For no studs located within the mounting area, level the wall bracket and mark all four screw
locations.
For concrete walls, level the wall bracket and mark all four screw locations
Figure 1: Wall Bracket
Figure 2: Wall Bracket Installation
Continued next page
WARNING
THE WALL BRACKET MUST BE
SECURELY ANCHORED TO THE WALL
USING APPROPRIATE HARDWARE