SR Instruments SR Scales SR555i Operating And Service Manual Download Page 20

Model SR555

i

 Stand-On Scale 

Operating and Service Manual 
Part No. MAN555

i

_MICROBAN_201001 

 

Page 20 of 22 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel:  716-693-5977     Fax:  716-693-5854    URL:  

www.srscales.com

 

email:  

[email protected]

       Copyright 2020

 

S

Instruments, Inc. 

WARRANTY 

 

FOUR YEAR LIMITED WARRANTY 

Each

  S

  system  is  manufactured  with  high  quality  components.    SR  Instruments,  Inc. 

warrants  that  all  new  equipment  will  be  free  from  defects  in  material  or  workmanship,  under 
normal  use  and  service,  for  a  period  of  four  (4)  years  from  the  date  of  purchase  by  the  original 
purchaser.    Normal  wear  and  tear,  injury  by  natural  forces,  user  neglect,  and  purposeful 
destruction are not covered by this warranty.  Warranty service must be performed by the factory 
or  an  authorized  repair  station.    Service  provided  on  equipment  returned  to  the  factory  or 
authorized repair station includes labor to replace defective parts.  Goods returned must be shipped 
with transportation and/or broker charges prepaid.  SR Instruments, Inc.’s obligation is limited to 
replacement  of  parts  that  have  been  so  returned  and  are  disclosed  to  SR  Instruments,  Inc.’s 
satisfaction  to  be  defective.    The  provisions  of  this  warranty  clause  are  in  lieu  of  all  other 
warranties,  expressed  or  implied,  and  of  all  other  obligations  or  liabilities  on  SR  Instruments, 
Inc.’s part, and it neither assumes nor authorizes any other person to assume for SR Instruments, 
Inc.  any  other  liabilities  in  connection  with  the  sale  of  said  articles.    In  no  event  shall  SR 
Instruments,  Inc.  be  liable  for  any  subsequent  or  special  damages.    Any  misuse,  improper 
installation, or tampering, shall void this warranty.  

DAMAGED SHIPMENTS 

Title  passes  to  purchaser  upon  delivery  to  Transportation  Company.    Purchaser  should  file  any 
claims for shortage or damage with  the delivery carrier and should refuse any shipment  that has 
obvious external damage.  

RETURN POLICY 

All products being returned to SR Instruments, Inc. require a Return Goods Authorization number 
(RGA).  To receive an RGA, call our Customer Service at 716-693-5977 ext 103 or toll-free in the 
USA and Canada at 800-654-6360 ext 103. 

When  inquiry  is  made,  please  supply  model  and  serial  numbers,  purchase  order  and  reason  for 
return.  

Generally,  deleted,  damaged,  and  outdated  merchandise  will  not  be  accepted  for  credit.    A 
minimum restocking charge of 15% will be assessed on return of current merchandise unless scale 
is returned because of SR error.  

No returns will be accepted after 30 days. 

All  returns  are  to  be  shipped  FREIGHT  PREPAID  to:    SR  Instruments,  Inc.,  600  Young  Street, 
Tonawanda, NY 14150. 

RESTOCKING FEE 

 

15% fee

 will be assessed on return of current merchandise 

 

No fees

 will be charged if the scale is returned because of an error on the part of SR 

Instruments, Inc. 

 

No returns 

accepted after 30 days

.

  

Summary of Contents for SR Scales SR555i

Page 1: ...BAN_201001 Page 1 of 22 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S by S I...

Page 2: ...CTION 8 STORAGE AND TRANSPORTATION 8 CLEANING AND DISINFECTING 9 SPECIFICATIONS 10 BUTTON FUNCTIONS 11 BASIC SYSTEM OPERATION 12 BATTERY REPLACEMENT 14 THEORY OF OPERATION 15 CALIBRATION 16 CONFIGURIN...

Page 3: ...ea DISPLAY UNIT WITH CABLE FIVE 5 SET SCREWS IN PLACE 1 ea PACKAGE OF SIX 6 C CELL BATTERIES 1 ea MEDICAL GRADE AC POWER SUPPLY SR555i AC ONLY 1 ea LOCTITE 1 ea 1 8 ALLEN WRENCH 1 ea QC INSPECTION SH...

Page 4: ...Base Assembly collar and seat firmly Re install set screws in Base Assembly collar and tighten securely NOTE If an optional printer has been ordered go to Page 6 INSTALLING OPTIONAL PRINTER before pro...

Page 5: ...the Cable Clamp and reinstall the Cable Clamp leaving just enough slack to alleviate any tension on the Cable exiting the Platform Securely tighten the Cable Clamp screw Excess cable MUST NOT contact...

Page 6: ...andrail Tighten all six 6 screws securely INSTALLING OPTIONAL HEIGHT BAR STEP 1 Figure 4 Remove the set screw on the back of the Display Unit 1 and in the Base Assembly 2 STEP 2 Slide the Height Bar 7...

Page 7: ...epresentation of the patient s weight The low power microprocessor circuitry allows the SR555i to derive its power from six 6 common C cell batteries that will provide up to 10 000 weight readings bef...

Page 8: ...dded to help reduce the growth of bacteria as part of a medical center s approach to creating a cleaner healthcare environment For more information visit https www microban com sr scales STORAGE and T...

Page 9: ...as Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disinf...

Page 10: ...OWER DOWN Approximately 30 seconds adjustable to 300 seconds ENTER Stores displayed reading in memory RECALL Recalls last stored stable weight height and BMI AVERAGING Automatic digital filter POWER S...

Page 11: ...when stable Auto stores stable weight in memory SEND PRINTER EHR Press to send stored values to EHR or to printer Output values include time date weight height and BMI Also indicated on display when p...

Page 12: ...or DOWN arrow buttons to select between PRINT INVERTED and PRINT NORMAL Press ENTER to save changes UP Press UP to adjust height up from the default to increase the scale s on time or to select a digi...

Page 13: ...using a cane for support on the scale place the cane on the scale while zeroing the system This will ensure that the patient s NET weight will be displayed CALCULATING BMI Press to calculate BMI When...

Page 14: ...8 Place the scale on its side and open the battery compartment cover located in the bottom of the scale base STEP 3 Remove and replace ALL six 6 C cell batteries Refer to diagram on the battery compa...

Page 15: ...s serving to normalize the sensitivity voltage out per unit of weight applied of each bridge The offset potentiometer produces a small current which nulls the output of the amplifier for an unloaded s...

Page 16: ...maximum scale capacity Put aside a subset of weight that is less than half of the combined weight DO NOT USE barbells or uncalibrated weights STEP 2 Zero the scale by pressing and holding ZERO WEIGH b...

Page 17: ...Use the UP arrow button to select the digit and the DOWN arrow button to change digit Press ENTER to save changes STEP 4 Press the MENU button until HALF 500 00 Lb is displayed Change HALF to the val...

Page 18: ...ation Mode on the display board Figure 10 STEP 6 Place the display panel into the display housing Align the display panel with the four holes in the display housing Secure display panel with the four...

Page 19: ...Wait five seconds then re install the battery and try the WEIGH button again The display lights appear to work but do not respond to button activation Check to ensure the membrane switch label is cor...

Page 20: ...abilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no...

Page 21: ...and Service Manual Part No MAN555i_MICROBAN_201001 Page 21 of 22 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com...

Page 22: ...AN555i_MICROBAN_201001 Page 22 of 22 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments...

Reviews: