Squibb-Taylor A120MAN Installation, Operation & Maintenance Manual Download Page 1

A120MAN IOM

1 of 7

www.squibbtaylor.com         1.800.345.8105

While this information is presented in good faith and believed to be accurate, Individuals using this literature must exercise their independent judgment in evaluating product selection and determining 

product appropriateness for their particular purpose, system requirements and certifications. The manufacturer reserves the right to change product designs and specifications without notice.

   Failure to follow these instructions or to properly install and maintain this equipment could result in personal injury 

 

   or death. Equipment must be installed, operated and maintained in accordance with federal, state and local codes.

 

   The installation must also comply with NFPA No. 70 and ANSI K61.1, (CGA G-2.1) standards and/or local authority having            

 

   jurisdiction. Only personnel trained in the proper procedures, codes, standards and regulations of the Anhydrous Ammonia 

 

   industry shall install and service this equipment.

214.357.4591     DALLAS TEXAS     800.345.8105

Distributed By Squibb Taylor

.com

www.

Scope of the Manual

This instruction manual covers installation, operation, 

&  maintenance for the A120MAN Manual Release for 

1 1/4” (A120) & 1 1/2” (A125 & A15) internal valves 

manufactured by Marshall Excelsior Co. for outdoor 

Anhydrous Ammonia (NH3) applications.  

March 2021

Installation, Operation, & Maintenance Manual For 

A120MAN Remote Manual Release

NOTE:  REFER TO THE INSTRUCTION MANUAL SUPPLIED WITH THE INTERNAL VALVE OR SQUIBB TAYLOR’S WEBSITE FOR ALL 

 

             WARNINGS, CUSTOMER NOTIFICATIONS, SPECIFICATIONS,  OPERATION, CAUTIONS, MAINTENANCE,  & PARTS. CALL 

 

             SQUIBB TAYLOR @ 800.345.8105 WITH ANY QUESTIONS BEFORE PROCEEDING

  

KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER.

IMPORTANT: 

  USER SAFETY RESPONSIBILITY STATEMENT FOR SQUIBB TAYLOR PRODUCTS

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN 

CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

•  This document and other information from Squibb Taylor and authorized distributors provide product or system

 

options for further investigation by users having technical expertise.

•  The user, through its own analysis and testing, is solely responsible for making the final selection of the system and  

components and assuring that all performance, endurance, maintenance, safety and warning requirements of the                

application are met. The user must analyze all aspects of the application, follow applicable industry standards, and      

 

follow the information concerning the product in the current product catalog and in any other materials provided

 

from Squibb Taylor or authorized distributors.

To the extent that Squibb Taylor or authorized distributors provide component or system options based upon data or 

specifications provided by the user, the user is responsible for determining that such data and specifications are suitable           

and sufficient for all applications and reasonably foreseeable uses of the components or systems.

Part Description

Qty.

Manual Release with Break-Away Coupling

1 Pc.

Lever

1 Pc.

Plate

1 Pc.

Cotter Pin

1 Pc.

Hex Mounting Cap Screws

2 Pc.

Carabinier

1 Pc.

Parts List

Carabinier

Cap

 

Screws

Manual  Release

Plate

Lever

Cotter Pin

Break-Away 

Coupling

Patent

Pending

!

WARNING

             

The A120MAN Fail Safe Remote Manual Release must be used for 

ANHYDROUS AMMONIA APPLICATIONS ONLY

.

            DO NOT USE IN LPG/PROPANE SERVICE.    

                                                                   

Summary of Contents for A120MAN

Page 1: ...LL SQUIBB TAYLOR 800 345 8105 WITH ANY QUESTIONS BEFORE PROCEEDING KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER IMPORTANT USER SAFETY RESPONSIBILITY STATEMENT FOR SQUIBB TAYLOR PR...

Page 2: ...e valve Start threading the screws into the valve 6 Test the Open operation of the Manual Release Move the Lever to the right until it stops release it The plunger on the Manual Release should have re...

Page 3: ...fore Sending To Field For Use To Open Valve 1 Always open the internal valve before opening any other valves in the line 2 Move the lever to the half open rapid equalization position Operational Schem...

Page 4: ...tart threading the screws into the valve 6 Test the Open operation of the Manual Release Move the Lever to the right until it stops release it The plunger on the Manual Release should have retracted i...

Page 5: ...lize pressure When the main poppet clicks open move the operating lever fully open 3 Open other line valves slowly to avoid sudden surges which could slug the excess flow valve shut 4 If the excess fl...

Page 6: ...the Break Away Insert Manual Release Cable 6 Discard the Break Away Insert Inspect the Crimped Ends of the Cables for wear or deterioration Discard Break Away Insert 8 Replace the Manual Release Cable...

Page 7: ...111911 A125 60AM Angle 60 GPM 111913 A125 60SM Straight 111916 A15 45AM 1 1 2 MNPT 1 1 2 FNPT Angle 45 GPM 111918 A15 45SM Straight 111921 A15 60AM Angle 60 GPM 111923 A15 60SM Straight WARNING For An...

Reviews: