Chapter 13
SEITAL S.r.l.
Rev. 6 of 24/11/08
Page 13-34
Use and maintenance handbook: Centrifugal separator
SE 40CX
HYDRAULIC SYSTEM DIAGRAM - TAB. 21
A
Product inlet DN50 DIN11851
B
Heavy phase outlet (buttermilk) DN40 DIN11851
C
Light phase outlet (cream) DN25 DIN11851
D
Operating water inlet G 3/4”
E
Operating water outlet DN40 DIN11851
F
Solids outlet DN80
Operating water unit
CV4 Check valve
CP4 Surge tank pump
SK4 Surge tank
PSC4 Pressure switch
MN4 Manometer
CF4 Operating water filter
PCV4 Pressure reducer
PSC0 Pressure switch - limiting the minimum water pressure
YV1 Operating water solenoid valve (bowl opening)
BV1 Ball valve (emergency)
BV0 Ball valve (emergency)
YV0 Operating water solenoid valve (bowl closing)
MN0 Manometer
Buttermilk outlet
MN1 Manometer
MV1 Micrometric valve
Cream outlet
MN2 Manometer
MV2 Micrometric valve