![SPXFLOW APV CU4plus AS-i Instruction Manual Download Page 22](http://html1.mh-extra.com/html/spxflow/apv-cu4plus-as-i/apv-cu4plus-as-i_instruction-manual_1352861022.webp)
APV_CU4plus_AS-interface_UK-3_062019.indd
UK
Control Unit
CU4plus AS-interface
Instruction Manual UK-3
APV
22
4. Mechanics and Pneumatics
4.5.
Technical data / Standards
Material:
PA6.6/PA12
Ambient temperature:
-20 to +70 °C, -4 to +158 °F
EU:
EMC 2014/30/EU (89/336/EEC)
Standards and environmental audits:
protective class IP 67 EN 60529/
complies with NEMA 6
EMV interference resistance EN
61000-6-2
EMV emitted interference EN61000-6-4
AS-interface certification according to
specification V3.0
vibration/oscillation EN60068-2-6
safety of machinery DIN EN ISO
13849-1
Air hose:
6 mm / ¼" OD
Pressure range:
6–8 bar
Compressed air quality:
quality class acc. to DIN ISO 8573-1
-
content of solid particles:
quality class 3,
max. size of solid particles per m³
10000 of 0,5 μm < d < 1,0 μm
500 of 1,0 μm < d < 5,0 μm
-
content of water:
quality class 3,
max. dew point temperature -20 °C
For installations at lower temperatures
or at higher altitudes, additional
measures must be considered to reduce
the pressure dew point accordingly.
-
content of oil:
quality class 1,
max. 0,01 mg/m³
The oil applied must be compatible with Polyurethane
elastomer materials.