Site Selection
Considerations
Foundation & Drainage
The Votator II should be located on a firm foundation, angled to
allow liquids to drain away from the unit.
Clearances
•
The rear and sides of the unit, or unit cluster, should have
adequate clearance to provide easy access for maintenance.
•
The front of the
Horizontal
unit should have the following
minimum clearances to allow for removal of the mutator
shaft:
6 x 84 Votator II - 102 in (259 cm)
6 x 72 Votator II - 90 in (230 cm)
6 x 48 Votator II - 71 in (180 cm)
6 x 36 Votator II - 59 in (150 cm)
6 x 24 Votator II - 40 in (102 cm)
•
The bottom of the
Vertical
unit should have the following
minimum clearances to allow for removal of the mutator
shaft:
6 x 84 Votator II - 96 in (244 cm)
6 x 72 Votator II - 84 in (214 cm)
6 x 48 Votator II - 66 in (168 cm)
6 x 36 Votator II - 54 in (137 cm)
6 x 24 Votator II - 48 in (122 cm)
Leveling the Unit
The
Horizontal
Votator II should be leveled lengthwise (along the
length of the cylinder) and crosswise by adjusting the feet on the
legs.
For units that will perform CIP, set the level for a forward pitch of
0.3 degrees (1/16 inch per foot).
If CIP is not required, set the level to what will give the best
drainage for the cylinder.
Electrical Power
Connections
The following electrical components for the Votator II require
connection in accordance with the electrical schematics in this
manual, tagged vendor specifications, and local regulations:
DANGER:
The Votator II operates
with high voltage. Electrical work
should be performed by a
Licensed Electrician in
accordance with local regulations.
•
Drive Motor
Each cylinder is furnished with a 3-phase, multi-voltage gear
motor with a horsepower rating per the application:
Std. Votator II accepts 7-1/2 HP (5.5 kW), 10 HP (7.5 kW), 15
HP (11kw) or 20 HP (15 kW); Extra Heavy Duty Votator II
accepts 25 HP (18.8 kW), 30 HP (22.5 kW) or 40 HP (30 kW).
Motor is fixed speed and suitable for use with a variable fre-
quency controller.
•
Hydraulic Pump Motor
(
Vertical
units only)
A 3/4 (0.5 kW) horsepower, fixed speed motor. A variable fre-
quency controller