background image

Operating Instructions,  Form No. 1000090,  Back sheet 4 of 6

TROUBLESHOOTING GUIDE

WARNING

To help prevent personal injury, any repair work or troubleshooting must be done by qualified personnel
familiar with this equipment.

Use the proper gauges and equipment when troubleshooting.

NOTE:

Depending on the type of pump, it is often best to check for leaks by using a hand pump and applying
pressure  to  the  suspect  area  without  the  motor  running.  Watch  for  leaking  oil  and  follow  it  back  to  its
source.

Plug the outlet ports of the pump when checking for leakage to determine if the leakage is in the pump or
in the wrench or tool.

Refer to the Parts List included with your particular pump when using this troubleshooting guide.

PROBLEM

CAUSE

SOLUTION

Electric motor does not run

WARNING: To help prevent

personal injury, disconnect
power supply before removing
cover. Any electrical work should
be performed by a qualified
electrician.

1. Pump not turned ON.

2. Unit is not plugged in.
3. No voltage supply.

4. Broken lead wire or defective

power cord plug.

5. Defective switches.
6. Defective motor.
7. Defective starter relay.
8. Defective remote switch.
9. Worn brushes.
10. Circuit breaker tripped because

total amperage draw too high for
existing circuit.

11. Overheated motor (single-phase

motor only). Magnetic starter
disengaged (three-phase motor
only). Thermal protector open.

12. Faulty thermal protector (single-

phase motor). Faulty magnetic
starter (three-phase motor).

1. Flip toggle switch to "Run"

position.

2. Plug in unit.
3. Check line voltage. Check reset

button on power panel.

4. Replace defective parts.

5. Check switches.
6. Repair or replace motor.
7. Replace defective parts.
8. Repair or replace remote switch.
9. Replace brushes.
10. Add an additional circuit or use

alternate circuit.

11. Wait for motor to cool before

restarting. Reset thermal
protector (Single-phase motor
will reset automatically.)

12. Replace.

Summary of Contents for Power Team PE55TWP

Page 1: ...d by improper operation or installation The hydraulic power unit can be ordered with building block flexibility The customer can choose from a variety of motors controls reservoirs and other options B...

Page 2: ...ER SUPPLY Never use an ungrounded power supply with this unit The pump must be compatible with existing line voltage Disconnect the pump from the power supply when performing maintenance or repair on...

Page 3: ...a clean funnel and filter Fill with hydraulic oil to 1 2 from the top of the filler hole Replace filler cap with the breather hole in the filler cap open 4 Cycle the pump with wrench attached several...

Page 4: ...operation IMPORTANT After eliminating trapped air from a large work holding system retract the wrenchs and refill the pump reservoir to 1 2 from the top of the filler hole Adjusting The Pressure Regu...

Page 5: ...mp to allow air to be released through the pump reservoir Hydraulic Fluid Level 1 Check the oil level in the reservoir after each 10 hours of use Proper oil level is 1 2 from the top of the fill hole...

Page 6: ...il Place the pump and motor assembly with gasket on the reservoir and thread the ten screws Tighten securely and evenly Adding Oil To The Reservoir 1 Wrench must be fully retracted and the power suppl...

Page 7: ...rm No 1000090 Sheet No 4 of 6 Rev 3 Date 25 May 2012 REASSEMBLY SPECIFICATIONS NEEDLE BEARING INSTALLATION SPECIFICATIONS HIGH PRESSURE PUMP ASSEMBLY BOLT TIGHTENING SEQUENCE BRUSH HOLDER ARMATURE INS...

Page 8: ...before removing cover Any electrical work should be performed by a qualified electrician 1 Pump not turned ON 2 Unit is not plugged in 3 No voltage supply 4 Broken lead wire or defective power cord pl...

Page 9: ...m top of filler hole with wrench retracted 2 Check quick disconnect couplings to wrench Inspect couplers to ensure that they are completely coupled Occasionally couplers have to be replaced because th...

Page 10: ...ere are no visible leaks the high pressure pump subassembly may be leaking Remove all parts Check the valve head assembly body for any damage to the seat area Clean and reseat if necessary Inspect for...

Page 11: ...replaced because one check does not stay open in the coupled position 2 Check valve operation and inspect parts Replace if necessary 3 Increase air pressure Pump delivers excess oil pressure 1 Faulty...

Page 12: ...os nuevos se deben a una instalaci n o uso inadecuados La unidad de potencia hidr ulica puede solicitarse con flexibilidad de unidad modular El cliente puede elegir entre una variedad de motores contr...

Page 13: ...uesta a tierra La bomba debe ser compatible con la tensi n de la l nea existente Desconecte la bomba de la alimentaci n el ctrica antes de realizar cualquier tarea de mantenimiento o reparaci n en la...

Page 14: ...5 cm por debajo de la parte superior de la boca de llenado Vuelva a colocar el tap n de la boca con el orificio del respiradero del tap n abierto 4 Accione la bomba con la llave instalada varias veces...

Page 15: ...E despu s de purgar el aire atrapado en un sistema extenso retraiga las llaves y rellene el aceite del dep sito de la bomba hasta 1 25 cm por debajo de la parte superior de la boca de llenado Ajuste d...

Page 16: ...e la bomba Nivel del l quido hidr ulico 1 Compruebe el nivel de aceite del dep sito cada 10 horas de uso El nivel adecuado de aceite est en 1 25 cm por debajo de la parte superior de la boca de llenad...

Page 17: ...rmemente A adir aceite al dep sito 1 Las llaves deben estar completamente retra das y la alimentaci n el ctrica desconectada al a adir aceite al dep sito 2 Limpie toda el rea que rodea la boca de llen...

Page 18: ...n 4 de 6 Rev Fecha 25 May 2012 Conjunto de la bomba de alta presi n unidad de 5 000 o 10 000 psi Siga la secuencia indicada Lubrique los tornillos debajo de la cabeza y en las roscas Apriete a 180 pul...

Page 19: ...realizados por un electricista cualificado 1 La bomba no est encendida ON 2 La unidad no est enchufada 3 No hay suministro el ctrico 4 Cable roto o enchufe del cable de alimentaci n defectuoso 5 Conmu...

Page 20: ...e las llaves Inspeccione los acoplamientos para asegurarse de que est n completamente insertados En algunas ocasiones es necesario sustituir los acoplamientos porque la retenci n esf rica no permanece...

Page 21: ...encontrarse en el subconjunto de la bomba de alta presi n Desinstale todas las piezas Revise el cuerpo del conjunto del cabezal de la v lvula para comprobar si el rea de asiento est da ada Limpie y re...

Page 22: ...n r pida 2 V lvula defectuosa 3 Presi n de aire inadecuada s lo para el modelo de motor neum tico 1 Man metro defectuoso 2 La v lvula de seguridad no est bien ajustada 7 Sustit yalas 8 Aumente la pre...

Page 23: ...rch eine nicht sachgem e Bedienung oder Montage verursacht Diese Hydraulikpumpen k nnen im Baukastenprinzip nach individuellem Kundenwunsch zusammengestellt werden Da dabei eine Vielzahl verschiedener...

Page 24: ...ird STROMVERSORGUNG Verwenden Sie auf keinen Fall ein nicht geerdetes Netzkabel Die Pumpe muss f r die vorhandene Netzspannung ausgelegt sein Unterbrechen Sie vor Beginn der Wartungs oder Reparaturarb...

Page 25: ...n Tankdeckel wieder auf Achten Sie dabei darauf dass die Entl ftungs ffnung im Deckel ge ffnet ist Lassen Sie die Pumpe mit angeschlossenen Drehmomentschl sseln einige Arbeitstakte laufen Fahren Sie d...

Page 26: ...zbereit WICHTIG Lassen Sie die Drehmomentschl sselzylinder nach dem Entl ften gro er Anlagen einfahren und bef llen Sie den Pumpentank bis auf 1 2 Zoll unterhalb der Einf ll ffnung Einstellen des Druc...

Page 27: ...ustreten kann Stand der Hydraulikfl ssigkeit 1 berpr fen Sie alle zehn Betriebsstunden den lstand im Tank Der Tank muss bei eingefahrenen Drehmomentschl sselzylindern bis auf 1 2 Zoll unterhalb der Ei...

Page 28: ...e zehn Schrauben ein Gleichm ig und fest anziehen Auff llen von l in den Tank 1 Der Drehmomentschl sselzylinder muss vollst ndig eingefahren sein und der Motor muss ausgeschaltet sein wenn l in den Ta...

Page 29: ...gebildeten Reihenfolge montieren Bereiche unter dem Kopf und Gewinde schmieren Anziehen auf 180 in lbs Beim Austausch der B rsten oder des Ankers m ssen die in der Abbildung gezeigten Ma e den vorgege...

Page 30: ...Abdeckung abnehmen S mtliche Elektroarbeiten d rfen nur von einem Fachmann ausgef hrt werden 1 Pumpe nicht eingeschaltet 2 Stecker der Pumpe ist nicht eingesteckt 3 Keine Spannung vorhanden 4 Defektes...

Page 31: ...ngen um sicherzustellen dass sie korrekt angeschlossen sind Manchmal m ssen die Kupplungen ausgetauscht werden weil das Kugelventil aufgrund von Verschlei erscheinungen nicht ge ffnet bleibt 3 Entl ft...

Page 32: ...kpumpe undicht sein Entfernen Sie alle Teile berpr fen Sie den Ventiltelleraufbau auf evtl Besch digungen am Sitzbereich Reinigen und nachschleifen sofern erforderlich Teile auf Besch digungen berpr f...

Page 33: ...n ge ffneter Position stehen bleibt 2 berpr fen Sie die Ventilfunktion und berpr fen Sie die Teile Tauschen Sie sie ggfl aus 3 Luftdruck erh hen Die Pumpe liefert zu hohen ldruck 1 Manometer fehlerhaf...

Page 34: ...mentation hydraulique peut tre command e avec la flexibilit du bloc modulaire Le client a le choix entre plusieurs moteurs commandes r servoirs et autres options En raison du grand nombre d options di...

Page 35: ...e avec la tension du r seau D brancher la pompe de sa source d alimentation avant d effectuer des travaux de r paration ou d entretien Si l alimentation de l unit est endommag e ou si le c blage inter...

Page 36: ...rer un entonnoir propre avec un filtre Remplir d huile hydraulique jusqu 1 2 du sommet de l orifice de remplissage Reposer le bouchon avec l vent ouvert 4 Actionner la pompe avec la cl branch e plusi...

Page 37: ...tionnement normal IMPORTANT Apr s avoir purg l air emprisonn dans un syst me de retenue pour des travaux lourds r tracter les cl s et remplir le r servoir de la pompe jusqu 1 2 du sommet de l orifice...

Page 38: ...servoir de la pompe Niveau d huile hydraulique 1 V rifier le niveau d huile du r servoir toutes les 10 heures de service le niveau d huile correct se situe 1 2 du sommet de l orifice de remplissage av...

Page 39: ...huile dans le r servoir 1 Lors de l appoint d huile dans le r servoir la ou les cl s doivent tre r tract es et l alimentation coup e 2 Nettoyer tous les abords du bouchon de remplissage avant de d po...

Page 40: ...e haute pression mod le 5 000 ou 10 000 psi Monter dans l ordre indiqu Lubrifier sous la t te et sur les filets Serrer au couple de 180 in lbs Lors du remplacement des balais ou de l induit les dimens...

Page 41: ...intervention sur le syst me lectrique doit tre faite par un lectricien qualifi 1 La pompe n est pas mise en marche 2 Appareil non branch 3 Pas de tension d alimentation 4 Fil rompu ou cordon d alimen...

Page 42: ...s sont bien branch s Il est parfois n cessaire de remplacer les raccords parce que le contr le bille ne reste pas ouvert en raison de l usure 3 Purger le syst me 4 V rifier et serrer la ligne d aspira...

Page 43: ...t une fuite interne V rifier les contr les bille de l entr e ou de la sortie de la pompe haute pression 1 tancher les raccords du tuyau qui fuient avec du produit d tanch it pour tuyaux 2 Nettoyer rem...

Page 44: ...des 2 Valve d fectueuse 3 Pression pneumatique inad quate moteur pneumatique uniquement 1 Manom tre d fectueux 2 Valve de s curit mal r gl e 7 Remplacer 8 Augmenter la pression pneumatique 9 Nettoyer...