600 Series

Electric Demand Drains
Models:  EDD 601-04, EDD 602-04, EDD 603-04, EDD 604-04

F OR M N O.: 7428306    R EVI S I ON: 09/2013

R EAD AN D U N D E R STAN D TH I S MAN UAL PR I OR TO OPE RATI N G OR S E RVI CI N G TH I S PR OD U CT.

I N STR U CTI ON MAN UAL

Summary of Contents for Hankison 600 Series

Page 1: ...emand Drains Models EDD 601 04 EDD 602 04 EDD 603 04 EDD 604 04 FOR M NO 7428306 R EVI S ION 09 2013 R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT I...

Page 2: ...CONTENTS GENERAL INFORMATION 1 1 0 FUNCTION 1 2 0 INSTALLATION 2 3 0 MAINTENANCE 6 4 0 TROUBLESHOOTING GUIDE 7 5 0 ENGINEERING DATA 8 6 0 DIMENSIONS 8 7 0 COMPONENTS 9 WARRANTY...

Page 3: ...inuously registers the liquid level As soon as the container is filled a fixed waiting period begins during which more condensate accumulates After the waiting time has expired the pilot valve 4 is th...

Page 4: ...7 3 4 with 1 of slope Lead discharge pipe 6 from the top into collecting line 7 Prior to the start up always carry out a leak test and verify the correct engagement of the control unit Incorrect Inst...

Page 5: ...remove the plug if there is one and guide the cable 4 for the power supply through 9 Connect the cable 4 with terminals X1 1 1 1 2 5 10 Install the cables as shown see also terminal assignment in the...

Page 6: ...ration The contacts X 2 1 2 3 are potential free External test remote control X 3 1 external test IN1 X 3 2 GND Contacts connected test active discharge Contact open test inactive The contacts X 3 1 3...

Page 7: ...5 2 3 Electrical Diagram Pos 52 Beko Technische D okumentati on Installati on BEKOMAT E Schema 0 mod_1233758178163_2901 docx 13497 1 1 Electric diagram...

Page 8: ...removing the union nut OR remove the screws 6 from the angle nozzle 7 OR remove the screws 8 at the intermediate adapter 9 and remove the latter from the service unit by pulling it downwards 7 Check...

Page 9: ...e discharge Feed and or outlet line shut off or blocked Worn parts seals valve core diaphragm Control printed circuit board defective Service unit defective Minimum pressure not reached Maximum pressu...

Page 10: ...mm ALARM SIGNAL ELECTRICAL CONNECTION INLET Models 601 603 Models 602 604 Min Max Operating Pressure see type plate 18 PSI 230 psi 12 PSI 230 psi Min Max Air Temperature see type plate 34 F 158 F 34...

Page 11: ...Circuit board 5 Sensor 6 Lower part of the cover 7 Cable bushing 8 Sealing mat 9 Service unit 10 Hose connector 1 4 11 O ring 20 x 2 12 Intermediate adapter 13 Screw M6 x 12 14 O ring 14 x 1 78 15 Ang...

Page 12: ......

Page 13: ...nance items requiring routine replacement are not warranted Unauthorized service voids the warranty and any resulting charge or subsequent claim will not be paid Products repaired or replaced under wa...

Page 14: ...nkison americas spx com www hankisonintl com Improvements and research are continuous at SPX Specifications may change without notice ISSUED 09 2013 Form No 7428306 Revision None COPYRIGHT 2013 SPX Co...

Reviews: