8
ENGINEERING DATA
SPECIFICATIONS
MODEL
Rated Capacity
1
(scfm)
Inlet /Outlet
Connections
Dimensions - inches (mm)
Net Weight
lbs (kg)
Height
Width
Length
FLX 1.1
75
NPT 1”
29.6
(751)
14.3
(363)
23.7
(603)
120
(54.5)
FLX 1.2
100
NPT 1”
28.0
(711)
14.3
(363)
30.7
(781)
147
(66.5)
FLX 2.1
200
NPT 2”
30.0
(761)
17.4
(443)
37.8
(961)
217
(98.5)
FLX 4.1
400
NPT 2”
35.9
(911)
19.4
(493)
43.7
(1,111)
335
(152)
FLX 4.5
450
NPT 2”
35.9
(911)
19.4
(493)
43.7
(1,111)
368
(167)
FLX 5.5
550
NPT 2”
40.6
(1,032)
19.4
(493)
47.4
(1,203)
437
(198)
1
Rated Flow Capacity - Conditions for rating dryers are in accordance with ISO 7183 (Option A2).
Compressed air at dryer inlet: 100 psig (6.9 barg) and 100°F (38°C); ambient air temperature: 100°F (38°C), operating on 60 Hz power
supply.
2
Refer to dryer data plate for refrigerant charge.
ELECTRICAL DATA
MODEL
Power Supply
Power
Consumption
(kW)
Refrigerant
Voltage
Phase
Hz
FLX 1.1
115
1
60
0.54
R-134a
FLX 1.2
115
1
60
0.64
FLX 2.1
230
1
60
1.30
R-407c
FLX 4.1
230
1
60
2.55
FLX 4.5
1
460
3
60
2.75
FLX 5.5
1
460
3
60
3.05
1
Please be advised that while models FLX 4.5 and FLX 5.5 are NEC compliant, they have not been NRTL tested or certified. As such, all pur-
chasers of these models are responsible for ensuring that these models are suitable for their intended use and that these models do not
violate any applicable laws, rules, regulations or codes of the jurisdiction in which these models will be used. If you have any questions or
concerns about these model’s suitability for your use, please do not hesitate to contact your authorized Hankison representative.
Please also be aware that Hankison expects to make a NRTL certified version of this model available later in 2017.
Summary of Contents for FLEX FLX 1.1
Page 23: ......