JL/X130 - 1680
6.6.1 Diagram of airflow for frame 4 and 5
This diagram shows a side view of a unit in
an enclosure. This is the recommended
method for arranging the
flow of cooling air. The fan in the JL/X will
draw air into the top and bottom air intakes of
the unit.
There are 2 air inlet filters mounted on the
door. One adjacent to the lower air intake of
the unit and the other adjacent to the upper
air intake of the unit.
The exhaust air is exiting the enclosure via
the venting kit assembly which is shown with
the cowl fitted on the roof of the enclosure.
If this hot exhaust air is likely to raise the
temperature of the air being drawn in, then
further measures must be taken to direct it
away from the system.
Air Intake
IMPORTANT. Ensure 200mm area
top and bottom of drive for
unrestricted air entry.
Venting Kit
ensures
exhaust air
does not
mix with
input air.
Air Intake
Lift
Points
Air Intake
Air Intake