Anybus Option Modules
4.4.2 Cyclic Data
The Cyclic Data (Process Data) is transferred using the Producing Assembly and Consuming
Assembly.
•
The Producing Assembly “Input Data” (T
g
O) must be configured to match the
number of words used by the FIELDBUS
GET
GET
FROM
FROM
s.
•
The Consuming Assembly “Output Data” (O
g
T) must be configured to match the
number of words used by the FIELDBUS
GOTO
GOTO
s.
4.4.3 Acyclic Data
Parameters can be accessed acyclically from the Scanner/PLC by Set_Attribute and Get_
Attribute CIP object services.
Class
= 162 (A2h)
Instance
= parameter number
Attribute
= 5
Size
= 2 (2bytes)
For example:
409)SUMMER
409)SUMMER
1
1
INPUT
INPUT
2
2
is
Class:Instance:Attribute:Size 162:409:5:2
4.4.4 Electronic Data Sheet
Ethernet/IP eds files:
005A002B00370100.eds
PLX or JLX
M40
005A0000002E0100.eds
PLX or JLX
M30 2-Port
005A000000630200.eds
PLX or JLX
M30 1-Port