background image

1

5

3

2

4

9

Pre-Filter Setup/Install

This is the point where you will need to shut the main water supply off and 
adapt your plumbing in and through the system.  We recommend you 
plumb a shut off valve before the pre-filter housing.

  Locate the area where 

the system is going to be installed.  Locate aluminum pre-filter mounting bracket 
with hex bolts and washers.  Mount the pre-filter bracket to the wall (hex bolts 
into wall with washers).  

Note that the bracket should be screwed into the 

studs in the wall as the weight of the pre-filter once soaked in water will 
add weight. (approximately 24 pounds) 

Now connect the pre-filter housing 

head to the mounting bracket with the hex bolts provided.  Plumb the water from 
the main water supply into the Inlet side of the pre-filter head.  Install lubed o-ring 
in groove on top of the blue pre-filter housing.  Locate pre-filter and install it onto 
small pipe stand inside the housing.  Screw the housing to the head as tight as 
you can without the pre-filter housing wrench.  Now take the wrench and tighten 
down hand tight

Summary of Contents for CSF1

Page 1: ...592 WWW SPRINGWELLWATER COM You get the best of both worlds when you combine the benefits of our high tech SpringWell FutureSoft and environmentally friendly salt free water softener and our whole hou...

Page 2: ...on main water supply line CAUTION Do not install on well water unless you have spoken to a customer service representative first 1 Bypass Valve 2 1 MNPT Fittings x2 3 Mounting Bracket for Pre Filter 4...

Page 3: ...PSI Operating Temperatures 36 120 F Pre Filter Change Replacement Every 6 9 Months Media Change Replacement Every 6 Years or 1 Million Gallons CF4 Tank Width 10 Tank Height 54 58 with head Flow Rate...

Page 4: ...4 Level Tanks If the tank is not perfectly straight carefully lift the tank straight up a few inches and tap it on the ground until the tank stands vertical and fits snuggly into the tank boot...

Page 5: ...he 1 PVC elbows Install bypass valve to head of tank hand tight Be sure the bypass valve is in the on position Now install PVC elbow to inlet side Locate the hose bib assembly and connect it to the In...

Page 6: ...te the hose bib assembly and connect it to the Inlet side Connect a water hose to the opposite end of the hose bib assembly Put the bypass valve in the on position Turn the water on slowly to about ha...

Page 7: ...4 Turn water off and disconnect the water hose 5 Connect water the hose to outlet side and turn the water on slowly to full strength 6 Allow water to run for 5 minutes 7 Disconnect the hose and connec...

Page 8: ...Turn the water on slowly and only halfway on and allow the water to run for 15 20 minutes Turn water off and disconnect the water hose Connect water hose to Outlet side of the filter head and turn wat...

Page 9: ...washers Note that the bracket should be screwed into the studs in the wall as the weight of the pre filter once soaked in water will add weight approximately 24 pounds Now connect the pre filter housi...

Page 10: ...in water supply back on Check for leaks If there are no leaks slowly turn the bypass valves to the on position Go to a faucet inside and slowly turn the cold water on about halfway and let it run for...

Page 11: ...11 Warranty Information For more information on our warranty please visit www springwellwater com warranty...