INSTALLATION

The TankJet

®

 78M is easy to install. The TankJet 78M 

connects to a supply tube with a simple retaining clip. There 

are two different size options for inlet connections to the 

TankJet 78M; ¾" & 1". The supply line should be standard 

smooth bore 16 gauge (.065" thick) stainless steel tube of 

the appropriate size. A 9/64" or 3.5mm hole should be drilled 

through the supply tube according to the diagram below.

Slip the supply tube into the inlet of the unit, aligning the 

holes. Insert the retaining clip and swing it down until it 

locks. It should wrap around the neck of the inlet, but still fit 

loosely.
The TankJet 78M unit will only operate properly in the 

suspended vertical position (inlet at top).

NOTE: In order to maintain 3-A sanitary compliance, all 

units intended for CIP must be mounted in the suspended 

vertical position in order to ensure proper drainage. Other 

orientations must be either returned to the suspended 

vertical position or removed after operation and cleaned 

out-of-place.

Inlet Size

“A”

3/4"

1/4" (6.35mm)

1"

3/8" (9.52mm)

A

OPERATION

Refer to drawings on pages 9 thru 11 for parts list.

Specifications

Inlet Connection:

3/4" or 1" slip-fit

Operating Pressure Range: 

25 − 125 psi (1.7 - 8.3 bar)

Max. Operating Temp: 

200°F (93°C)

Flow Capacity: 

13 − 37 gpm (49.2 – 140.1 l/min)

Effective Cleaning/Dia.: 

To 25 ft. (7.6 m) maximum

Installation Hole Dia.: 

2.87" (3" Tri-Clamp Flange Connection)

Approximate Weight:

4.1 lbs. (1.9 kg)

Recommended Strainer: 

50 mesh (not included)

Summary of Contents for TankJet 78M

Page 1: ...TankJet 78M Tank Cleaners USER GUIDE MI TJ78M spray com This unit meets the requirements of 3 A Sanitary Standard 78 Spray cleaning devices intended to remain in place 78 03 Auth No 1040...

Page 2: ...t includes but is not limited to Protective hat Safety glasses or face shield Chemical resistant gloves and apron Long sleeve shirt and long pants NOTE Always remember to carefully read the chemical m...

Page 3: ...icals impingement drainage soils etc CAUTION If chemicals hazardous materials operations and equipment are used in conjunction with this cleaning equipment it is the responsibility of the user to esta...

Page 4: ...ly The TankJet 78M unit will only operate properly in the suspended vertical position inlet at top NOTE In order to maintain 3 A sanitary compliance all units intended for CIP must be mounted in the s...

Page 5: ...not infringe upon any copyright patent or trademark THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THOSE CONCERNING MERCHANTABILITY AND...

Page 6: ...Rotary Housing 12 to keep the assembly in place The Hub Cap 18 and Dowel Pin 13 may not line up perfectly on the first attempt to line them up simply spin the Hub Cap 18 in either direction till the...

Page 7: ...TARY HOUSING BEARING 12 CP116030 316L ROTARY HOUSING 13 CP116031 316L DOWEL PIN 14 CP116040 RUL MAIN BEARING 15 CP116035 316L STEM 16 CP116024 2 175 316L NOZZLE HUB 17 CP116042 RUL HUB CAP BEARING 18...

Page 8: ...e Road P O Box 7900 Wheaton IL 60187 7901 USA Tel 1 800 95 SPRAY Intl Tel 1 630 665 5000 Fax 1 888 95 SPRAY Intl Fax 1 630 260 0842 Email info spray com www spray com MI TJ78M Tank Cleaner Rev 8 21 20...

Reviews: