9
Your system is a self
-
contained heating system that requires power for the main panel. This system must be pared
with a control panel dedicated to the nozzle on/off control.
4.1 CONNECTIONS
Connect all process lines and blue conditioning lines to the tanks, pumps and nozzles. Please note the nozzle is sym-
metrical, and inlet/outlet water lines can be reversed. Your nozzle(s) are electrically actuated, and strictly hydraulic in
nature. Connect the cable for each nozzle, and wire in appropriately. See the manual for the appropriate Spraying Sys-
tems control panel schematics and reference drawings. Main air is configured to supply the panel and remote compo-
nents with a single connection.
Note:
All conditioning line hoses should be connected in series, and never in parallel.
Hoses on the main frame assembly goes from the conditioning fluid to the pump outlet and to the jacketed nozzle(s),
returning through the jacketed hose to the components at the base of the tank, then exit at the top of the tank and
returns to the standpipe. This allows for air relief of the conditioning circuit at that connection. When initially filling
the heating circuit, DI water is suggested at temperatures below 180°F (potable water could be used). For tempera-
tures 180°F
-
200°F, the system requires a glycol solution, typically 50/50. All air vents should be turned to the open
position indicated. They are automatic and will close when the air has fully escaped. Once all air bubbles have been
relieved, hand
-
tighten the 1/2G sensor being careful not to over tighten. An air pocket could initially reside in the level
switch on the stand pipe that can be relieved by loosening the 1/2G sensor connection recognizable by an O
-
ring.
CAUTION: The AccuCoat® MV10 Heated Spray System is powered by wiring into 230VAC 1 ø service. Do not
connect power until all wiring, and hookup of the system is complete.
WARNING: The air supplied to the machine must be clean, free of moisture and lubricating fluids; failure to do
this voids all warranties.
SECTION 4
SYSTEM HOOK
-
UP