background image

RA 1

5

ELECTRICAL CONNECTIONS

The luminaire is designed to operate with a 100V to 
240V supply, 50-60Hz, according to the lamp used.

Before and during the installation, make sure you follow 
the guidelines below:
• Always check the earth wiring for the line being used.
• Verify that the lamp voltage is correct for the main 

voltage

• Do not use lamps other than the ones indicated on 

the lamp table

• There are no fuses inside the unit, if it is necessary  

they should be installed in the mains

• The luminaires can be connected to a dimmer

INSERTING AND CHANGING THE LAMP

- Loose the knob 

 and rotate the accessory locking 

cover 

 upwards

- Remove the safety net 

- Replace the lamp without touching the glass bulb
- Insert the safety net again in its guides
- Re-place the accessory locking cover 

 and screw in 

The accessory locking knob 

④.

Please note that when changing the lamp,  the position 
of the luminaire fixture must not necessarily be 
changed so that the focus of the luminaire fixture can 
stay still.

DESCRIPTION OF THE LUMINAIRE

Referring to images on page 2:

① 

  Suspension yoke

  Safety net

  Accessory guides

 

  Accessory locking knob

  Accessory locking cover

⑥ 

Tilt adjustment knob

INTRODUCTION

The luminaire you have bought complies to 2006/95/EC, 
2004/108/EC and 2011/65/EU European Directives.
The label on the rear of the luminaire lists the following 
information:
• model
• mains supply voltage (V)
• lamp wattage (W)
• IP protection index
• maximum allowed ambient temperature in °C
• maximum temperature of the body in °C 
• minimum distance from flammable surface
• information to find the position 0° of the luminaire: 

when the tip of the arrow points upwards 

• maximum tilt angle range. These limits, imposed by 

the lamp manufacturer, should not be exceeded as 
they would reduce the lamp’s useful life or lead to its 
deterioration.

INSTALLATION

• The luminaires are intended for professional use only 

so they have to be installed and used by qualified 
technicians.

• The products are intended for indoor use: 

consequently they have to be protected from humidity 
and rain, if used in different conditions (IP 20)

• Do not mount the luminaire on or near a flammable 

surface

• Please note carefully the notes written on the labels 

of the luminaires.

• Do not forget to connect a safety cable, if required by 

local country safety regulations

• For safety requirements the net shall be mounted 

on the front of the lamp to prevent any large glass 
fragments from falling in case of breaking.

• The luminaire can be either suspended or placed on a 

plane surface.

WARNING: replace immediately the 
lamp if visibly damaged, even if still 
working.

WARNING: The luminaires must always be 
earthed

WARNING: For safety reasons always discon-
nect the projector from the mains before 

opening it to change the lamp.

Summary of Contents for Ribaltina RA 1

Page 1: ...Manuale utente User manual cod RA 1 Ribaltina...

Page 2: ...otlight srl non potr essere ritenuta responsabile di danni derivanti dalla non osservanza di dette istruzioni SAFETY WARNING Before using this product read the present instructions carefully Spotlight...

Page 3: ...1 65 UE La targhetta localizzata sul retro del faro contiene le seguenti informazioni modello massima tensione di alimentazione in V massima potenza della lampada in W indice di protezione IP massima...

Page 4: ...corre tener puliti il pi possibile la rete di protezione ed il diffusore Per far questo dopo aver scollegato il faro dalla rete di alimentazione si pu aprirlo per pulire con uno straccio soffice inumi...

Page 5: ...ives The label on the rear of the luminaire lists the following information model mains supply voltage V lamp wattage W IP protection index maximum allowed ambient temperature in C maximum temperature...

Page 6: ...t luminaire performance both the safety net and the reflector must be kept as clean as possible To do so after disconnecting the luminaire fixture from the mains both the safety net and reflector can...

Page 7: ...0 200 R7s 3520 2900 2000 K9 230 300 R7s 5600 2900 2000 K1 230 400 R7s 9900 2900 2000 P2 11 230 800 R7s 24400 3200 150 P2 20 230 1000 R7s 30000 3200 300 300 140 215 Dimensioni mm e peso Dimensions mm a...

Page 8: ...Spotlight s r l Via Sardegna 3 20098 S Giuliano Milanese Milano Italy Tel 39 02 98830 1 Fax 39 02 98830 22 E mail info spotlight it www spotlight it RA 1...