background image

Rev. 1.02

FollowLED 450 DMX

cod.  VD LED 450 CW DMX - VD LED 450 WW DMX

Manuale utente - User manual

Summary of Contents for FN LED 450 CW DMX

Page 1: ...Rev 1 02 FollowLED 450 DMX cod VD LED 450 CW DMX VD LED 450 WW DMX Manuale utente User manual ...

Page 2: ...nte le istruzioni che seguono Spotlight srl non potrà essere ritenuta responsabile di danni derivanti dalla non osservanza di dette istruzioni SAFETY WARNING Before using this product read the present instructions carefully Spotlight srl will not be responsible for damage resulting from instructions not being followed Fig 1 ...

Page 3: ... IN OUT IN CONSOLE B MASTER EFFECT MANUAL DMX IN OUT IN DMX OUT DMX IN DMX OUT OUT IN A 230V OUT IN OUT IN DMX OUT DMX IN DMX OUT OUT IN DMX OUT DMX IN B 452 352 1044 Fig 2 Kg 22 Installazione con segnale DMX DMX connection Fig 2 Fig 3 Installazione MASTER SLAVE MASTER SLAVE configuration Dimensioni mm e peso Dimensions mm and weight ...

Page 4: ...al costruttore o dal suo servizio di assistenza Sottoporre il faro a revisione almeno una volta all anno per controllare l integrità delle parti elettriche e meccaniche e l aggiornamento del software RICICLAGGIO Il prodotto deve essere riciclato o smaltito secondo la direttiva 2002 96 CE DESCRIZIONE DEL PROIETTORE Riferendosi ai disegni di pag 2 Staffa Maniglia per regolazione inclinazione faro Ma...

Page 5: ...alizzazione delle impostazioni di default ovvero la Modalità di Funzionamento attualmente impostata Se il faro è comandato dal dmx il display dopo 3 secondi mostra una videata con modo e indirizzo dmx Altrimenti mostra lo stato del potenziometro LEGENDA SETUP BACK PREV NEXT ENTER Premendo il tasto setup si accede alle impostazioni e si naviga attraverso i sottomenu agendo sui pulsanti NEXT e PREV ...

Page 6: ...ARD Rotazione di 180 del display Standard tasti a destra del display DISPLAY STANDBY OFF ON OFF Selezionando ON il display si spegne automaticamente dopo 60 secondi di inutilizzo DEFAULT SET Imposta il default per tutti i parametri utente FACTORY SETTING Riservato al Costruttore Impostazioni di fabbrica Fan Mode Vi sono tre modalità di controllo ventole L utente può scegliere la modalità tramite i...

Page 7: ...180 ms 116 125 210 ms 126 135 240 ms 136 145 270 ms 146 155 300 ms 156 165 330 ms 166 175 360 ms 176 185 390 ms 186 195 420 ms 196 205 450 ms 206 215 480 ms 216 225 510 ms 226 235 540 ms 236 245 570 ms 246 255 600 ms 4 FAN 0 255 Ventola da velocità MINIMA a STANDARD valori in Volt impostabili in menu Factory Setting 4 STROBE vedere apposito paragrafo 5 SERVICE vedere apposito paragrafo 8 bit 1CH C...

Page 8: ...modalità DMX DMX_PERSONALITY_ DESCRIPTION Ottenimento descrizione testuale modalità DMX DEVICE_MODEL_DESCRIPTION Descrizione testuale del device model MANUFACTURER_LABEL Descrizione testuale manufacturer SENSOR_DEFINITION SENSOR_VALUE Visualizzazione dei valori letti dal sensore di temperatura espresso in decimi di grado Celsius CANALE SERVICE valido se canale dmx STROBE in fascia SERVICE Ch Nome ...

Page 9: ...VD LED 450 DMX 9 ...

Page 10: ...ervice the luminaire at least once a year to check the integrity of the electrical and mechanical parts and for any possible software update On this purpose only contact qualified dealers to guarantee correct and full servicing RECYCLING The product must be recycled or disposed of according to Directive 2002 96 CE DESCRIPTION OF THE LUMINAIRE Referring to drawings on page 2 Picture 1 Yoke Luminair...

Page 11: ... by the display of the default settings ie the currently set operating mode If the luminaire is DMX controlled after 3 seconds the display will show the mode and DMX address Otherwise it will show the potentiometers status LEGENDA SETUP BACK PREV NEXT ENTER Pressing the SETUP key you access the settings and browse through the submenus by pressing the NEXT and PREV buttons which in case of value ty...

Page 12: ...he wireless DMX module UNLINK Enter to Unlink Esc to Exit To unlink the fixture from the wireless dmx transmitter MENU OPTIONS Item Value Def Description LED DELAY OFF 30 60 600 ms 240 ms Delay time on LED output This parameter is ignored when you select a personality containing the Delay channel DIMMING CURVE LINEAR QUADRATIC HALO QUADRATIC Gamma Correction OUT FREQUENCY 500 800 1000 1500 10000 1...

Page 13: ...09 120 270 ms 121 132 300 ms 133 144 330 ms 145 156 360 ms 157 168 390 ms 169 180 420 ms 181 192 450 ms 193 204 480 ms 205 216 510 ms 217 228 540 ms 229 240 570 ms 241 255 600 ms 4 FAN Fan from MINIMUM to STANDARD speed values in Volts can be set in the Factory Setting menu 5 STROBE See the relevant paragraph 6 SERVICE See the relevant paragraph 8 bit 1CH Ch Name DMX Value 1 DIMMER 0 255 From Off ...

Page 14: ...taining textual description of DMX mode DEVICE_MODEL_DESCRIPTION Text description of the device model MANUFACTURER_LABEL Text description manufacturer SENSOR_DEFINITION SENSOR_VALUE Display of the values read by the temperature sensor expressed in tenths of Celsius degree CANALE SERVICE valid if dmx channel STROBE is on SERVICE area Ch Name DMX value xx SERVICE 0 5 INACTIVE 6 11 LED DELAY OFF 12 1...

Page 15: ...VD LED 450 DMX 15 ...

Page 16: ...VD LED 450 DMX Spotlight s r l Via Sardegna 3 20098 S Giuliano Milanese Milano Italy Tel 39 02 98830 1 Fax 39 02 98830 22 E mail info spotlight it www spotlight it ...

Reviews: