23-7/16"
Water Inlets
Electrical Cord Location
6' cord length
H
C
Control Panel
depending on
positioning of
leveling legs
Drain Outlet
Exhaust
Outlet
4" diam.
6"
6"
Plastic
U-Clamp
Flexible
Drain Hose
(5' length)
4"
Side View (not to scale)
Data Sheet Includes Information On
Splendide
Product Model Number
WD2100 - (LD)
Splendide 2100 Laundry Center
Installation Location:
· Unit may be installed in recessed area,
closet, or alcove.
· Air Space Requirements: 0" on sides and
1" in front and back (from the case). Addi-
tional installation spacing needs to be
considered for easy installation, servicing,
and compliance with state and federal
codes.
· Floor must support at least 280 lbs. and be
a solid, level surface.
· When locating in a towable trailer or
watercraft, position the machine over the
axles or midship where movement is at a
minimum. Block unit in to prevent extreme
movement.
Electrical Requirements:
· Machine Voltage/Amperage: 115V, 13 Amp,
60Hz
· Connection: 3-prong plug with 6' cord is
provided with unit.
· Circuit/Protector: 3-wire single phase, 120V,
60Hz, AC, on separate 15-ampere circuit.
Standpipe Drain System/ Sink Draining
Requirements:
· Needs a 1 ¼" (3.2 cm) minimum diameter
standpipe with the minimum carry-away
capacity of 7 gallons (26 liters) per minute.
Top of standpipe must be at least 25" (62
cm) high and no higher than 34" (86 cm)
from the bottom of the washer.
· Outlet end of drain hose (provided with the
unit) must be at least 20" above bottom of
washer. An air break must be available at
the standpipe to avoid siphoning.
· Faucet Adapter Kit #154187104A is available
to allow for direct faucet connection. See
complete installation instruction on drain
hose draining directly into sink, connection
to dishwasher Wye fitting, and
disposer/drain connection in owners manual.
· Optional Drain-A-Way™ Pans are
available. Pan #PI-24 for cabinet or under-
counter installations. Pan #P-24 for free-
standing installations. Both are designed to
be drain plumbed.
Exhaust Requirements:
· DO NOT exhaust dryer into a chimney,
furnace, cold air duct, attic, crawl space, or
another duct used for venting
· If cabinet door is installed, a minimum of 8
sq. inches should be provided. Louvered
doors with equivalent air openings are
acceptable. Allow clearance behind the
door(s) to avoid rubbing between back of
cabinet door(s) and front of unit control
panel. Additional clearances for wall, door
and floor moldings may be required.
· Rigid or flexible metallic duct required.
Ducting must slope downwards and away
from the machine.
Never reuse data sheets. Data sheets are subject to change without notice. Never use data sheets for final installation criteria. Complete installation
instructions are available upon request and in the owner's manual that comes with the unit.
NOTE: Electrical Cord Location, Drain Outlet, Exhaust Outlet and Water Inlets are located on the
rear of the unit
Front Leveling
Legs
25"
Vent
Adapter
22-3/16"
total case depth*
23-3/8"
total depth including
vent adapter and door handle
NOTE: 24" minimum width entry doors and hallways recommended for ease of installation.
11/16"
34-11/16"
21-1/16"
2-1/4"
4-3/4"
1-3/8"
29-3/4"
2-1/2"
29-1/2"
2-1/2"
33-1/8"
to
33-1/2"
Front View (not to scale)
1-1/2"