background image

 

 

OSLT Calibration Kit  
2.4 mm (50 ohms) 

 
BN 533842 

 

Summary of Contents for BN 533842

Page 1: ...OSLT Calibration Kit 2 4 mm 50 ohms BN 533842 ...

Page 2: ...life of a calibration kit depends to a great extent on you Observe the information contained in these instructions and the enclosed documentation The more carefully you treat your calibration kit the longer it will provide dependable service Certification Spinner GmbH certifies that this product met its published specifications at the time of shipment from the factory Spinner GmbH further certifie...

Page 3: ...pe of Delivery 6 5 1 Offset Opens and Shorts 7 5 2 Broadband Loads 7 5 3 Adapters 7 6 Calibration Data 7 7 Identification of Component Serial Numbers 7 8 Data Sheet 7 9 Use and Preventive Maintenance 7 9 1 Cleaning Connectors 8 9 2 Gauging Connectors 9 9 3 Connection and Disconnection 9 10 Handling and Storage 10 11 Recalibration 10 12 Spare parts 10 13 Disposal 11 14 Warranty 11 15 Contacts 11 ...

Page 4: ...ial technical skills and must be executed by qualified personnel with reference to Start up information in the product documentation Keep the basic safety instructions and the product documentation in a safe place and pass them on to the subsequent users Symbols and safety markings Observe basic safety instructions Observe product documentation Danger of electric shock Warning Non ionised electro ...

Page 5: ...herwise specified Spinner products are not protected against penetration of liquids gases steam etc If this is not taken into account there exists the danger of electric shock for the user or damage to the product which can also lead to personal injury 8 Spinner products are not explosion proof They must not be operated in explosion prone areas 9 Never use the product under conditions in which con...

Page 6: ...ranteed The user is responsible for all personal injury and property damage resulting from improper use Reading the manual as well as adhering to all the information provided particularly the safety instructions is considered mandatory to comply with the intended use 5 Scope of Delivery The calibration kit BN 533842 includes the following items Offset open plug Offset open socket Offset short plug...

Page 7: ... is individually belonging to each component of the kit Using the individual calibration data for other components may result in reduced measurement accuracy 7 Identification of Component Serial Numbers In addition to the serial number of the kit the components of the kit have individual serial numbers too These serial numbers are listed in the file Calibration Data pdf on the USB stick The serial...

Page 8: ...tor should be kept clean and free of dirt and other debris Dampen a lint free swab with denaturised alcohol Gently rotate the swab in the interface around the inner conductor being careful not to stress or bend the pin Ensure that no foreign material remains in the interface after cleaning Ensure that the inner conductor of the connector has not been bent or damaged ATTENTION Only dampen the swab ...

Page 9: ...ductors are within the pin depth limits extended by the measurement uncertainty specified in the data sheet file 533842 BE pdf on the USB stick refer also to the above chapter Gauging Connectors Align the connectors carefully The plug inner conductor has to intrude concentrically into the bushing of the socket connector Push the connectors straight together and tighten the coupling nut hand tight ...

Page 10: ... hard material The plating and the mating plane surfaces may be damaged if the interface contacts any hard surface uncontrolled After any shock to a component e g drop down on the floor recalibration is recommended 11 Recalibration The suggested initial interval for recalibration is 12 months or 500 matings whichever comes first The actual need for recalibration depends on the use and the maintena...

Page 11: ...cross linked polystyrene and copper beryllium The user is responsible for disposing of the calibration kit in accordance with the national waste disposal regulations 14 Warranty Do not disassemble any component of the calibration kit The warranty is void if components are modified improperly handled or third party intervention or modification has occurred 15 Contacts SPINNER GmbH Headquarters Erzg...