ECDIS User Guide
13-10
65900012
Performance Monitor
The Performance Monitor folder displays the current operational
Transceiver (TCVR); selected from the Radar menu, see Interswitch
Control.
Before using the Performance Monitor (PM) select the following operating
parameters:
•
Master Display (Interswitch systems)
•
Transmit mode
•
Radar Video on
•
Gain setting at optimum level (if the setting is too low or too high
the four tuning arcs may not be visible).
Performance Monitor Operation
A non-logged on user can operate the PM and adjust the monitor mode
(Receiver or System) tune levels to determine if there has been a drop in
performance.
In a multi-node system the PM monitor tuning settings are distributed and
used by other nodes on the system.
To turn on the performance monitor (PM) tick the check box next to On.
In Operator mode the PM switches off automatically after 10
seconds.
If sector blanking is active the system displays a warning prompt informing
the operator that sector blanking is inhibited while the PM is switched on.
When the PM is operational and the monitoring mode tuning level is being
adjusted, four arcs are shown on the chart display. These arcs are
approximately 0.3NM apart and start at a range of between 6NM to 10NM.
The arcs extend from 290° to 320° (S Band), or from 155° to 185° (X
Band), with respect to the heading line, see the figure on the following
page.
Summary of Contents for Visionmaster FT ECDIS
Page 1: ...ECDIS User Guide Northrop Grumman Sperry Marine B V Part Number 65900012...
Page 2: ......
Page 4: ...ECDIS User Guide 65900012 iii Intentionally Blank...
Page 22: ...Table of Contents ECDIS User Guide xx 65900012...
Page 24: ...Overview ECDIS User Guide 1 2 65900012 Single System...
Page 42: ......
Page 68: ......
Page 132: ......
Page 284: ......
Page 312: ......
Page 396: ......
Page 404: ......
Page 462: ......
Page 478: ......
Page 484: ......
Page 520: ......
Page 531: ......