Targets
ECDIS User Guide
10-4
65900012
Tracked Targets Capacity
Single Node
Not relevant for ECDIS Watchmode
Multi- Node
The maximum number of targets that can be tracked on a multi-node
system is 200.
If the number of tracked targets reaches 95% of the system maximum a
caution is given;
System
Tracks Almost Full
. If the number of targets
reaches the maximum and the user attempts to acquire an additional target
a
System
Tracks Full
warning is raised and no further targets may be
tracked on the nodes.
On a three node system each node may track up to 100 targets
individually; but if the first node is tracking 50 targets and the second node
75 targets, the third node may only track up to 75 targets. In this case, the
System
Tracks Full
warning would be raised when an attempt is made to
acquire the 201
st
target, but the local
Tracks Full
warning would not be
raised since none of the nodes have reached their maximum.