Menomonee Falls, WI 53051
1-800-645-5398
www.
S
perry
I
nstruments.com
SPERRY
INSTRUMENTS
©2006 SPERRY INSTRUMENTS, INC.
OPERATING INSTRUCTIONS
BEFORE USE:
READ ALL OPERATING INSTRUCTIONS BEFORE USE. Use extreme
caution when checking electrical circuits to avoid injury due to electrical
shock. Sperry Instruments assumes basic knowledge of electricity on
the part of the user and is not responsible for any injury or damages due
to improper use of this tester.
OBSERVE and follow all standard industry safety rules and local
electrical codes. When necessary call a qualified electrician to
troubleshoot and repair the defective electrical circuit.
SPECIFICATIONS:
Operating Range:
80-250 VAC/DC, 60 Hz, CAT II 300V
Indicators:
Visual Only
Operating Environment:
32° - 104° F (0 - 32° C)
80% RH max., 50% RH above 30° C
Altitude up to 2000 meters. Indoor use.
Pollution degree 2. Accordance with IED-664.
Cleaning:
Remove grease and grime with clean, dry cloth.
OPERATION:
To test for voltage insert test leads into outlet or carefully touch test
leads to electrical contacts or circuit to be tested. If voltage is present the
neon indicator will glow. The brightness of the bulb will increase as the
voltage increases.
To test for the live side of an electrical outlet insert one probe into the
ground plug of the outlet while inserting the other probe in the alternate
sides of the outlet. The neon indicator will glow when the probe makes
contact with the live side.
SINGLE HAND OPERATION:
Sperry's patented design allows for convenient single hand testing of
outlets when the probes are snapped into the bottom housing of the
tester. Just insert the probes into the outlet and if voltage is present the
neon indicator will glow.
MODEL:
ET6102
VOLTAGE INDICATOR
Form # 374 4/06
Limited Lifetime Warranty
limited solely to repair or replacement; no warranty
of merchantability or fitness for a particular purpose. Product is warrantied to
be free of defects in materials and workmanship for the normal life of the
product. In no event shall Sperry Instruments be liable for incidental or
consequential damage.
Warning –
This product does not sense potentially hazardous
voltages below 80 volts. Do not use outside of the
marked/rated ranges indicated.
!
This unit is protected by the following US Patents: US Pat # 6,137,285
CAUTION – REFER TO THIS MANUAL
BEFORE USING THIS TESTER.
Double Insulation:
The tester is protected throughout by double
insulation or reinforced insulation.