Sperry instrument GMC-3000 Crimp-n-Test Operating Instructions Download Page 1

A. UTP/STP Cable Test Jack
B. Remote
C. Wiring Status Indicators
D. Test Button
E. Jumper Cables
F. RJ-45 (4 pair) Crimp Station
G.

 

RJ-11 (1,2 or 3 pair) crimp station

H. 

 

Built-in cutting and stripping blades

I.

  

High leverage design for easier crimping

OPERATING INSTRUCTIONS

MODEL: 

GMC-3000

 Crimp-n-Test

SAFETY WARNINGS

This instruction manual contains warnings and safety rules which 

must be observed by the user to ensure safe operation of the 

instrument and retain it in safe condition. Therefore, read through 

these operating instructions before using the instrument.

!

!

WARNING – Do NoT uSE oN lIvE CIRCuITS 

Note: Although the GMC-3000 is equipped with 8 position modular 

plug jacks, cables with smaller 6 position and 4 position connectors 

may also be tested. The user should be aware that the use of 

smaller connectors will reduce the total number of jack insertions 

over the life of the product.

TESTING PATCH CABlES 

1. Connect the main unit to one end of the cable to be tested.

2. Connect Remote unit to plug at far end of cable.

3. Push the TEST button to perform test.

4. Read LEDs to determine cable wiring status.

TESTING INSTAllED CABlES 

1.  Using the jumper cable, connect the remote unit to the wall jack 

or patch panel port to be tested.

2.  Using the second jumper cable, connect the main unit to the 

other wall jack or patch panel port to be tested. 

3. Push the TEST button to perform test.

4. Read status of LEDs to determine cable wiring status.

TEST RESulTS 
PASS Indicators

Shield

Standard Wiring

Green SHIELD LED indicates the 

Shield on the cable is correctly 

and continuously wired through 

the modular plug termination.

Four green LEDs on pairs 1-2,

3-6, 4-5, and 7-8. 

All four pairs are terminated 

correctly.

FAIl INDICAToRS

A flashing LED indicates that this wire pair has a fault. A flashing 

LED in the FAIL section will indicate which fault was detected. 

Multiple flashing LEDs indicate multiple pairs and/or multiple faults. 

Best practice is to correct cable faults until cable is verified as 

correct with appropriate green LEDs.

• SHoRT – A short circuit condition exists.

•  MISWIRE – Indicates the improper assignment of individual wire 

pairs to pins for the wiring schemes tested. Tester checks T568A, 

T568B, 10Base-T, and Token Ring configurations.

•  REvERSAl – Reverse wiring means the pin for 

one wire in a pair is connected to the opposite  

pin for the pair in the remote jack.

•  SPlIT PAIRS – Split pairs occur 

when the tip (positive conductor)  

and ring (negative conductor) of  

two twisted pairs are interchanged.

Note: The GMC-3000 will check a 

fault condition in the above  

descending order before detecting  

other fault conditions. The detection  

and indication of the presence of  

a fault is handled on a “one-per-test”  

basis. Once a fault is corrected, it  

is recommended the cable be  

tested again for other faults.

DEBuG MoDE
The DEBUG mode identifies which cable pairs have a wiring fault.  

It cycles through pairs displaying a test result for one pair at a 

time. From the series of LED indications, the failed pair and  

fault can be identified. In Debug mode, a short flash on PAIR  

LED is the pair under test. A long flash on PAIR LEDs is  

destination of test.
To DEBUG:
1. Press and hold TEST button until all LEDs light, then release.
2.  The pair identification LEDs and the FAIL LEDs work together in 

series to identify which pair is incorrect.

3.  If a series of two green LEDs light for a pair then that pair is 

wired correctly.

4.  A green pair LED followed by a red LED in the FAIL section 

identifies which pair is incorrect and identifies the fault.

5.  DEBUG cycles through the pairs twice before automatically 

shutting off.

6.  Pushing and quickly releasing the TEST button also turns  

tester off.

DEBuG Example #1 The Cable Fault is a SHORT on Pair 3-6, the 

DEBUG mode LED series will be as follows:
• Pair 1-2 will flash green-green as a good pair
•  Pair 3-6 will flash green on the pair LED followed by a red on the 

SHORT LED 

• Pair 4-5 will flash green-green as a good pair
• Pair 7-8 will flash green-green as a good pair

DEBuG Example #2 Following are some examples of potential 

sequences on pair 1-2 and interpretation of various fault conditions 

for that pair only:

1st 

Short
Flash

2nd 

long
Flash

Red Fault
LEDs

Fault Condition

1-2

1-2

No Red Light

Good Pair

1-2

1-2

Reversal

Pair Reversed 1-2  2-1

1-2

1-2

Short

Pin 1 Shorted to Pin 2

1-2

1-2,3-6

Short

1 or 2 shorted to 3 or 6

1-2

7-8

Miswire

Pin 1-Pin 7, Pin 2-Pin 8

1-2

7-8

Miswire, 

Reversal

Pin 1-Pin 8, Pin 2-Pin 7

1-2

1-2

Split Pair

Wire from 1-2 twisted 

with wire from another 

pair, continuity good

Above examples are for 1-2 pair, similar lights would relate to other 

pairs under test (short flash)

BATTERY REPlACEMENT
1.  Remove screws from back of main handle using a #1 Philips 

screwdriver. Carefully open tester.

2. Remove old batteries.
3.  Install a new 6 volt A544 1/2AA size battery or 4LR44 Button 

cell batteries.

4. Close tester and replace screws. Do not over tighten.

limited lifetime Warranty limited solely to repair or 

replacement; no warranty of merchantability or fitness for a 

particular purpose. Product is warrantied to be free of defects 

in materials and workmanship for the normal life of the product. 

In no event shall Sperry Instruments be liable for incidental or 

consequential damage.

1
2
3
4
5
6
7
8

Split

1
2
3
4
5
6
7
8

Terminal A

Terminal B

Crossover cable

1
2
3
4
5
6
7
8

Reversed

1
2
3
4
5
6
7
8

Tip

Ring

Roll

Marked tip (actually ring)

Marked tip (actually tip)

INSTRUCCIONES DE OPERACIÓN

A. Toma de prueba de 

cables UTP/STP

B. 

  

Cableado

C. Indicadores de estado del 

cableado

D. Botón de prueba
E. Cables de puente
F. Estación de engarzado 

RJ-45 (4 pares)

G. Estación de engarzado 

RJ-11 (1,2 ó 3 pares)

H. 

 

Hojas incorporadas para 

cortar y pelar

I.  Diseño de alto 

apalancamiento para facilitar 

engarzar

MODELO: 

GMC-3000 

Engarzados Y Prueba

ADvERTENCIAS DE SEGuRIDAD

Este manual de instrucciones contiene advertencias y reglas 

de seguridad que el usuario debe observar para garantizar el 

funcionamiento seguro del instrumento y mantener su estado sin 

presentar peligro. Por lo tanto, lea estas instrucciones operativas 

antes de usar el instrumento.

!

!

ADvERTENCIA – No SE DEBE uSAR EN CIRCuIToS 

ENERGIzADoS

Nota: Aunque el GMC-3000 está equipado con tomas de enchufe 

modulares de 8 posiciones, también pueden probarse conectores más 

pequeños de 6 posiciones y 4 posiciones. El usuario debe tener presente 

que el empleo de conectores pequeños reducirá la cantidad total de 

inserciones de la toma durante la vida útil del producto.

PARA PRuEBAS CABlES DE PARCHE

1. Conecte la unidad principal a un extremo del cable a probar.

2. Conecte la unidad remota al enchufe del extremo alejado del cable.

3. Pulse el botón TEST (prueba) para realizar la prueba.

4.  Lea las luces indicadoras (LED) para determinar el estado del 

cableado.

PARA PRuEBAS CABlES INSTAlADoS  

1.  Usando el cable puente conecte la unidad remota a la toma de 

pared o puerto de panel de parche a probar.

2.  Usando el segundo cable puente conecte la unidad principal a la 

otra toma de pared o puerto de panel de parche a probar. 

3. Pulse el botón TEST (prueba) para realizar la prueba.

4.  Lea las luces indicadoras (LED) de estado para determinar cómo está 

el cableado.

RESulTADoS DE PRuEBA
Indicadores de que PASA la prueba

Blindaje

Estándar Remoto

La luz indicadora verde (LED) 

SHIELD (blindaje) indica que el 

blindaje del cable está cableado 

correcta y continuamente a través de 

la terminación del enchufe modular.

Cuatro luces verdes indicadoras 

(LED) en pares 1-2, 3-6, 4-5 y 7-8. 

Los cuatro pares tienen 

terminaciones correctas.

INDICADoRES DE FAllA

Una luz indicadora (LED) destellante indica que este par de 

cables tiene una falla. Una luz indicadora destellante en la sección 

FAIL (FALLA) indica la avería que se detectó. Si hay varias luces 

indicadoras destellantes quiere decir que hay varios pares y/o fallas 

diversas. Lo mejor es corregir las fallas de cables hasta que se 

verifique que los cables están correctos con las luces indicadoras 

verdes (LED) adecuadas.

• CoRToCIRCuITo – Existe un cortocircuito.

•  CABlEADo INCoRRECTo – Indica la asignación indebida de pares de 

cables individuales a patillas para los esquemas de cableado probados. 

El probador revisa configuraciones T568A, T568B, 10Base-T y Token 

Ring.

•  INvERSIóN – Un câblage inversé signifie que la 

broche pour un fil dans une paire est raccordée à la  

broche opposée pour cette paire dans la prise distante.

•  PARES DIvIDIDoS – Los pares divididos ocurren 

cuando se intercambia la punta (conductor positivo)  

y el aro (conductor negativo) de dos pares trenzados.

1
2
3
4
5
6
7
8

Divididos

1
2
3
4
5
6
7
8

Invertido

1
2
3
4
5
6
7
8

Punta

Aro

Rodillo

Punta marcada (realmente aro)

Aro marcado (realmente punta)

F

G H

D

C

A

B

E

I

F

G H

D

C

A

B

E

I

Reviews: