background image

Vibration Meter

840063

Instruction Manual

Summary of Contents for 840063

Page 1: ...Vibration Meter 840063 Instruction Manual ...

Page 2: ...t do not yet exist or may be developed including photocopying recording or any information storage and retrieval system without the express permission from Sper Scientific INTRODUCTION 3 PANEL DESCRIPTION 3 OPERATING INSTRUCTIONS 4 GENERAL MEASUREMENT 4 PEAK 4 DATA HOLD 4 DATA RECORD 4 AUTO SHUT OFF 5 BATTERY REPLACEMENT 6 CLASSIFICATION RANGES 6 ISO 2954 SENSITIVITY RELATIVE TABLE 7 SPECIFICATION...

Page 3: ...ration The large display indicates RMS Peak min max hold low battery and auto power off Comes ready to use in a foam lined hard shell carrying case with a detachable strongly magnetic probe 9V battery and instructions PANEL DESCRIPTION 1 BNC Socket Plug 2 Display 3 Power Button 4 Hold Button 5 RMS Peak Selector 6 ACC VEL Selector 7 Recall Button 8 Record Button 9 Mini Plug 10 Input Socket 11 Magne...

Page 4: ...tion 5 Press the POWER BUTTON once to turn on the meter 6 If the surface material of the object you are testing is a non magnetic material hold the VIBRATION SENSOR and touch the tip to the object If the surface material is magnetic connect the VIBRATION SENSOR to the MAGNETIC BASE and touch it to the object s surface Peak Value Switch the RMS PEAK SELECTOR to the PEAK position Peak value 1 414 RM...

Page 5: ...in symbol along with the minimum value will appear on the display 4 To exit the memory record function press and hold the RECORD BUTTON for approximately 2 seconds The display will revert back to the current reading Automatic Shut Off This unit has a built in automatic shut off function to prolong battery life The meter will shut off automatically if no buttons are pressed within 10 minutes To dea...

Page 6: ...al motors of up to 15 KW Good 0 to 0 71 mm s Acceptable 0 72 to 1 80 mm s Still permissible 1 81 to 4 5 mm s Dangerous 4 5 mm s GROUP M Medium sized machines especially electrical motors with 15 to 75 KW output without special foundations Good 0 to 1 12 mm s Acceptable 1 13 to 2 80 mm s Still permissible 2 81 to 7 1 mm s Dangerous 7 1 mm s GROUP G Large machines on heavy foundations Good 0 to 1 80...

Page 7: ...Velocity 0 5 to 199 9 mm s 0 1 mm s Frequency 10 Hzto 1 KHz sensitivity relative during the frequency range meets ISO 2954 see pg 6 Calibration Point Velocity 50 mm s 160 Hz Acceleration 50 m s2 160 Hz Sampling Time Approximately 1 second Operating Conditions Temperature 0 to 50 C 32 to 122 F Humidity Less than 80 R H Power Supply Alkaline or heavy duty type DC 9V battery Power Consumption Approx ...

Page 8: ...y does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will break the waterproof seal and void the warranty To obtain warranty service ship the unit postage prepaid to SPER SCIENTIFIC LTD 8281 East Evans Road Suite 103 Scottsdale AZ 85260 The defective unit must be accompanied by a des...

Reviews: