Sper scientific 840022 Instruction Manual Download Page 1

Advanced Light Meter 

 

840022 

 

Instruction Manual 

 

SPER 
SCIENTIFIC 

LTD

[email protected]

www.ponpe.com

Summary of Contents for 840022

Page 1: ...Advanced Light Meter 840022 Instruction Manual SPER SCIENTIFIC LTD sale ponpe com www ponpe com ...

Page 2: ...ccurate response Results are easily read on the extra large LCD with bar graph Measures Foot Candles or Lux and offers high resolution 5 ranges selectable light source types Tungsten Fluorescent Sodium or Mercury max min peak hold RS232 output zero adjustment a tripod back automatic power off low battery and out of range indicators The sensor is cosine and color corrected and hermetically sealed t...

Page 3: ...ZERO SOURCE 15 16 1 Sensor Input 2 Display 3 Power Button 4 Hold Button 5 REC MAX MIN Button 6 RS232 Cover lifts 7 Lux FC Button 8 RS 232 Output see 6 9 Range Button 10 Source Button 11 Zero Button 12 Tripod Screw 13 Stand 14 Battery Cover 15 Sensor Plug 16 Photo Sensor sale ponpe com www ponpe com ...

Page 4: ... life After approximately 10 minutes without activity no buttons pushed the meter will automatically shut off To disable this feature press the REC MAX MIN 5 button Press the POWER 3 button to manually turn the meter off 3 B Hold During measurement press HOLD 4 to freeze the measured value HOLD and the value are displayed Press the HOLD 4 button again to exit 3 C Peak Hold During measurement press...

Page 5: ...ecurely in place and the meter turned on use the RANGE 9 button to select the 40 00 Lux range digits appear Press the ZERO 11 button and the 0 00 LUX should be displayed To maintain accuracy annual laboratory calibration is recommended and available from Sper Scientific 5 BATTERY REPLACEMENT Replace the battery when the low battery icon is displayed In spec measurements may be made for several hou...

Page 6: ... USB Adaptor Cable 840090 Water Resistant Instrument Pouch 840092 Bench Top Tripod 840093 Field Tripod 850080 Software The 16 digits data stream will be displayed in the following format D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status D0 End Word D1 D8 Display reading D1 LSD D8 MSD E g If the display reading is 1234 then D8 to D1 is 00001234 D9 Decim...

Page 7: ...F S 400 0 36 6 400 0 0 1 4 000 360 4 000 1 40 000 3 600 40 000 10 400 000 10 000 400 000 100 100 000 3 rdg 0 5 F S 100 000 for reference only Foot Candle 4 000 0 3 720 0 001 3 rdg 0 5 F S 40 00 3 35 37 20 0 01 400 0 33 5 372 0 0 1 4 000 335 3 720 1 40 000 930 37 200 10 9 300 3 rdg 0 5 F S 9 3000 for reference only Accuracy tested by a standard parallel light tungsten lamp of 2856 K sale ponpe com ...

Page 8: ... substituted if available This warranty does not cover probes batteries or damage resulting from accident misuse or abuse of the product To obtain warranty service ship the unit postage prepaid to SPER SCIENTIFIC LTD 7720 E Redfield Rd Suite 7 Scottsdale AZ 85260 WWW SPERSCIENTIFIC COM INFO SPERSCIENTIFIC COM The defective unit must be accompanied by a description of the problem and your return ad...

Reviews: