4.3

 

SYMBOLS 

Symbol

 

Meaning

 

 

 

 

General or specific warnings

 

 

 

 

See instructions for use

 

 

Lubricate 

 

 

 

Lot number 

 

 

 

Product code 

 

 

 

Serial Number 

 

 

 

The product is compliant with the requirements of Directive 93/42/EEC 

Caution

: U.S.  Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner 

4.4

 

WARRANTY AND SUPPORT 

Spencer Italia S.r.l. guarantees that products are without defects for a period of 

one year from the date of purchase.  

For any information regarding the correct interpretation of the instruction manual, the use, maintenance, installation and restore of 
the product, contact the Spencer customer care service ph. +39.0521.541111, fax +39.0521.541222 or e-mail [email protected]

In order to facilitate the assistance service,  please always indicate the lot  number (LOT) or serial number (SN) shown on the  label 
applied on the box or on the device. 

Conditions for warranty and assistance can be viewed on

 

http://support.spencer.it. 

 

Note

: Record and store; these instructions, lot (LOT) or serial number (SN) if any, date and place of purchase, date of first 

use, date servicing, user names and comments. 

 

5.

 

WARNINGS 

The  warnings,  notes  and  other  important  safety  information  are  indicated  in  this  section  and  are  clearly  visible 
throughout the entire manual. 

At least every 6 months, is important to verify if updated User Manuals are available or there is any change involving 
your product. This information is freely available on the website 

http://support.spencer.it

 in the section “User manuals” 

and “Product Updates”. 

User training  

Note

: Laboratory testing, post production tests, instruction manuals cannot always consider every possible scenario for 

use.  This  means  that  in  some  cases  the  performance  of  the  product  could  be  notable  different  from  results  to  date 
obtained. 

Instructions  are  continually  being  updated  and  are  under  tight  surveillance  of  fully  qualified  staff  with 

adequate technical formation. 

 

Regardless of the level of experience gained previously with similar devices, it is recommended that you carefully read this  manual 
before installing, operating or using the product or carrying out  any maintenance. If in doubt, contact Spencer Italia S.r.l. to obtain 
the necessary clarifications. 

 

The product must be used by trained personnel only, having attended specific training for this device and not for similar products. 

 

The suitability of the user to use the product may be attested by the records of training, where the names of those trained, of the 
trainers, dates and place are Indicated. 

This register which certifies the eligibility of the operators to use the Spencer device must 

be  kept  for  a  period  of  10  years  after  the  disposal  of  the  device  itself.  This  register  will  be  made  available  to  the  competent 
Authorities and/or manufacturer if requested. In the absence of such documentation, sanctions will be applied. 

 

Do  not  allow  any  untrained  person  to  help  during  the  use  of  the  device,  because  they  could  cause  damage  to  the  patient  or  to 
themselves. 

 

The product should be operated only by personnel trained in the use of this product and not in others similar. 

 

Note: Spencer Italia S.r.l. is always at your disposal to organise product training. 

Installers training 

The installation of the device must be carried out only by qualified and trained staff authorized by Spencer Italia S.r.l. 
Timing  and  procedures  for  conducting  training  courses  shall  be  agreed  between  the  customer  and  our  Commercial 
offices. 

Summary of Contents for 520

Page 1: ...ly from the actual device Spencer Italia S r l assumes no responsibility for any errors contained herein or for damage accidents or consequences connected with the supply performance or use of this manual First edition 19 10 2015 Rev 0 19 10 2015 SPENCER ITALIA SRL Strada Cavi n 7 43044 Collecchio PR Italy www spencer it support spencer it e mail info spencer it service service spencer it Ph Tel 3...

Page 2: ... 14 12 5 LIFE SPAN 14 13 TROUBLESHOOTING 14 14 ACCESSORIES 14 15 SPARE PARTS 14 16 DEMOLITION 14 Warning The information contained in this document could be modified without any warning and is not to be intended as a commitment on behalf of Spencer Italia S r l Spencer products are exported to many countries and the same identical regulations are not always valid For this reason there could be dif...

Page 3: ...pt for the duration of the device and must accompany the device in case of change of ownership or destination If the operating instructions received relate to products not received you must immediately contact the manufacturer before use The Spencer product manuals can be downloaded in the updated revision from the website or can be requested by http support spencer it or by contacting the manufac...

Page 4: ...ways consider every possible scenario for use This means that in some cases the performance of the product could be notable different from results to date obtained Instructions are continually being updated and are under tight surveillance of fully qualified staff with adequate technical formation Regardless of the level of experience gained previously with similar devices it is recommended that y...

Page 5: ...ct with any source of combustion or inflammable agents Store in a cool dry dark place and do not expose to direct sun Do not store the device underneath any heavy objects which could cause structural damage Store and transport the device in its original packaging Failure to do so makes the warranty void Storage temperature from 20 C to 60 C Maintenance cleaning Spencer Italia S r l disclaims any l...

Page 6: ... the parameters given in the validated cycle as specified in the technical standards With reference to the D Lgs 24th February 1997 n 46 emended by D Lgs 25 01 2010 n 37 Acknowledgement of Directive 93 42 CEE and 2007 47 CE concerning Medical Devices we remind both public and private operators That in the exercise of their activity detect an accident involving a medical product are required to not...

Page 7: ...duct as this may cause injury to themselves or to other people The operators that use the device must have the physical ability to use it and good muscle coordination as well as presenting strong back arms and legs to raise and support and be able to grasp firmly the device with both hands Operators must be able to provide the necessary assistance to the patient Users should be able to lift and ha...

Page 8: ...olyurethane 12 Ground support feet Steel CHAIR MODE Size Stretcher mode Size GENERAL Total height 1305 Length with telescopic handles closed 1945 Width mm 545 Seat Backrest height 480 825 Length with telescopic handles opened 2055 Weight kg 14 2 0 5 Seat width 380 Depth Rear handles closed Rear handles opened Lying part height 100 Loading capacity1 kg 160 805 945 1 Maximum load capacity means the ...

Page 9: ...uch interference could cause malfunctions and injury to the patient and or rescuer Moreover the manufacturer will no longer recognize the product warranty and will accept no responsibility 10 FUNCTIONAL CHARACTERISTICS Element Description Function A Telescopic handles They can be used both in chair or stretcher mode for transport and lifting of the device They can be extracted to make these operat...

Page 10: ... patient on the device After patient positioning fasten the belts and tighten them to ensure a correct immobilization 11 2 Telescopic handles The telescopic handles have been made to facilitate lifting of the device when in stretcher mode or to make tilting easier when in chair mode They are kept in position by a mechanism that is inserted automatically when reaching the excursion limits both duri...

Page 11: ... reach a position suitable for lifting and transport It is not allowed to use the device with or without the patient on it using only the rear wheels The transport by lifting in chair mode is particularly indicated in confined spaces such as stairs For this operation the presence of more operators is required at least one at the front side and at least one at the rear side Proceed as follows Ensur...

Page 12: ...basic requirements foreseen by the manufacturer in following paragraphs are inspected All maintenance and periodic servicing activities must be registered and kept together with the servicing reports These documents have to be kept for a period of 10 years after the disposal of the device itself This register will be made available to the competent authorities and or manufacturer if requested Rout...

Page 13: ...s 1 and 2 must be fixed the upper and lower side of the backrest sheet A In the parts 3 and 4 must be fixed respectively the widest part and tighter one of the seat sheet B Do not pass the sheets around other part of the frame because movements of the device will be compromised After the correct installation of the sheet has been verified adjust the strap to ensure that the sheets are tight Use on...

Page 14: ...rame Verify that the new sheets are installed properly Wheels do not allow an easy sliding Dirt debris and absence of lubrication limit the rotation of the wheels Carry out cleaning and lubrication procedures described in paragraph 12 2 If the problem persist put the device out of service and contact the manufacturer The sheet doesn t support the patient s weight The quick release buckles are not ...

Reviews: