SPX X-ray
Industrial Imaging System
Page 35 of 44
SPX Series System Manual
118173-001 Rev. D
FAULT MESSAGES (Cont.)
Fault Descriptions
Fault Indicator
Description
Transformer OC Fault
Transformer Over Current Fault
LVPS-15V Fault
Low Voltage Power Supply -15V Under/ Over Voltage
LVPS+ 15V Fault
Low Voltage Power 15V Under/ Over Voltage
Watch Dog Fault
Firmware Timeout
Tube Head X-ray On Lamp Fault
X-Ray “on” Lamp Fault
Prewarn Lamp Fault
Front Panel Pre-warning Lamp Fault
Cooler Select Fault
X-ray Tube Cooler Fault
DC Rail Fault
DC Switch Voltage Drive Fault
AC Line Fault
Line Voltage Incorrect
Over Temp. Fault
Over Temperature Power Supply
Power Supply Fault
Power Supply Inhibited Due to 1 or More Faults
PT Interlock Fault
Pressure/Temperature Tube Head Fault
OV Fault
Over Voltage Fault
UV Fault
Under Voltage Fault
OC Fault
Power Supply Output Over Current Fault
UC Fault
Power Supply Under Current Fault
Over Power Fault
Power Supply Exceeded Power Rating
Filament Regulator Fault
X-Ray Tube Filament Current Regulator Not Working Properly
Inverter Fault
HV Transformer Primary Drive Not Working Correctly
Inverter OT Fault
Temperature on Inverter Driver too High
Cooler Interlock Fault
Coolant Not Flowing Through X-ray Tube
FP X Ray ON Lamp Fault
Front Panel X-Ray On Lamp Not Working
ARC Fault
Power Supply or X-Ray-Tube ARC Occurred
External Interlock Fault
External Interlock Pins A & B not Jumped
Light Confirm
External Light Fault