background image

pH 110 Meter 

PRODUCT MANUAL 

Item # 2120 

®

Summary of Contents for Fieldscout 2120

Page 1: ...pH 110 Meter PRODUCT MANUAL Item 2120 ...

Page 2: ...p m CST FAX 815 436 4460 e mail specmeters com www specmeters com Spectrum Technologies Inc 12360 S Industrial Dr East Plainfield IL 60585 General Overview 3 Data Logger Operation 4 GPS Connection 5 Logger Software 6 Specifications 8 Appendix 1 Time Zone Corrections 9 Service and Support 10 Warranty 11 General Overview 3 Data Logger Operation 4 Identifying the Correct Com Port 6 Logger Software 8 ...

Page 3: ...t field data with the pH 110 meter The logger can be used with or without GPS DGPS After a set of data has been collected it is transferred to a PC using the included software The data is in ASCII text file format and can be exported into mapping software or popular spreadsheet software for analysis NOTE THIS BOOKLET CONTAINS INSTRUC TIONS ON OPERATING THE DATALOGGER AND MAINTAINING THE pH PROBE I...

Page 4: ...oftware is attempted during this 10 second period the logger will remain in Com munication mode indefinitely The meter must be turned off and then on to change to Measurement mode see following section Measurement Mode Approximately 10 seconds after turning on the meter the LED light will glow steadily This indicates the logger is in Measurement mode In this mode you can calibrate the meter and re...

Page 5: ...y the Print button The Print button is on the lower right corner of the keypad next to the Range button If the readings are not being geo referenced the green LED will briefly flash off and then back on If the readings are being geo referenced see GPS Connection p 10 and a GPS signal is found the green LED will turn off for a slightly longer time then glow steadily If the readings are being geo re...

Page 6: ...per clip 1 Disconnect the meter from the serial cable 2 Click on the Com Port button on the main software screen This will bring up the Port Selection screen 3 Select the Com port to be tested and click on the Port Test button In the Port Test screen click the Test Port Now button Identifying the Correct Com Port ...

Page 7: ...isplayed this port may be the one connected to your serial cable and you can proceed to the next step 5 Place a paperclip on the end of the serial pin so that it touches both the tip of the pin and the metal area between the two black rings see fig 3 Again click on the Test Port Now button If the message Connection OK now appears this is the Com port connected to your serial cable Figure 2 Figure ...

Page 8: ...the meter so it is in Communication mode see Data Logger Operation p 4 In order to communicate through your com puter the COM port connected to your serial port must be selected For most machines this will be COM 1 If you are having trouble connecting try se lecting another COM port This can be done by clicking the COM port toolbar button or by clicking Select Comm Port from the File menu Meter Se...

Page 9: ... being extracted from the log ger When com pleted the Save Data As box will appear From here you can give the data file a de scriptive name and select a folder in which to save it The folder selection field on the right allows you to browse to any folder in your sys tem When the file has been saved the software will give you the option of immediately viewing the file The data file is stored as a c...

Page 10: ...cting the GPS signal The meter is again ready to take a reading when the LED returns to a steady glow If the data logger loses the GPS signal the LED will flash briefly be fore returning to Measurement mode In this case check the GPS battery status as well as the connec tion to the pH data logger GPS Settings Your GPS unit should be set to NMEA 0183 input output messages This standard requires you...

Page 11: ...nts without GPS 1 488 data points with GPS Operating Environment Weather Resistant Power 4 x AAA batteries Provides 40 hours of logging Software Requirements Windows 95 or higher Field Scout Software v 3 4 or higher included Specifications ...

Page 12: ...nton 8 San Francisco Los Angeles Vancouver 9 Anchorage 10 Honolulu 11 Wellington 13 Adelaide Melbourne Sydney 14 Vladivostok Brisbane 15 Seoul Tokyo 16 Beijing Hong Kong Manila Singapore Taipei 17 Hanoi Jakarta Vientiane 18 Calcutta New Delhi 19 Kabul Islamabad 20 Tehran Abu Dhabi Dubai 21 Moscow Nairobi Kampala Riyadh 22 Ankara Athens Helsinki Istanbul Cairo Johannesburg Harare 23 Amsterdam Barce...

Page 13: ... get the answer you need 2 Write down the events that led to the problem Have you changed anything in your computer recently Are you doing anything differently When Contacting Spectrum Technologies Inc please indicate that you need Technical Support Be prepared to 1 Provide details on the hardware and software configuration of your computer including manufacturer model number peripherals and versi...

Page 14: ...This warranty does not cover damage due to improper installation or use lightning negligence accident or unauthorized modifications or to inci dental or consequential damages beyond the Spectrum prod uct Before returning a failed unit you must obtain a Returned Materials Authorization RMA from Spectrum Spectrum is not responsible for any package that is returned without a valid RMA number or for t...

Page 15: ...15 ...

Page 16: ...a Logging pH Meter Type Electrical Equipment for Measurement Control and Laboratory Use Directive 89 336 EEC Standards EN 61326 1997 EN 55022 EN 61000 4 2 3 The meter also contains an add on data logger that has been installed in other products that have received CE certification Douglas L Kieffer Soil Water Products Manager March 4 2009 12360 S Industrial Dr E Plainfield IL 60585 800 248 8873 or ...