background image

R

1. Application

1.1 Designated use

Use with pressure gas cylinders for compressed high purity gases, gases dissolved 

under pressure and liquid gases to reduce the cylinder pressure and maintain an as 
constant as possible outlet pressure.

1.2 Non-designated use

Do not use pressure regulator for gases in the liquid phase.
Do not use for unsuitable gas types.

Do not use pressure regulator in operating conditions, that it was not designed for.

Do not use at temperatures below -30°C or above +60°C.

!

!

!

!

!

The system has to be used according to these instructions for use and especially the 

safety instructions!

5.2 Pressure regulators have always to be protected against damage (visual

 

inspection at regular intervals).

5.3 The adjustment of the relief valve (4) must not be altered!
5.4 Ensure perfect condition of seals, sealing surfaces and pressure gauges.
5.5 In case of malfunctions, e. g. an increase of the outlet pressure during the 

supply, or in case of leakage versus atmosphere or a defect pressure gauge, shut 
down the upstream gas supply and take the pressure regulator out of operation.

6. Shut-down

6.1 For longer interruptions or end of work:

Close the gas cylinder valve (1) first by releasing the hand knob (6) to 

depressurize the cylinder pressure regulator.

6.2 Before disassembly purge the regulator (where applicable) and make sure that 

pressure gauges (3) and (5) display zero pressure.

Contents

 

                                             

1. Application

1.1 Designated use

1

1.2 Non-designated use

1

1.3 Technical data

2

2. Safety instruction

2

3. Labelling

2

4. Start-up

3

5. Operation and maintenance

3

6. Shut-down

4

7. Repair

           4

8. Dimensions

4

 page

FE 121

 8. Dimensions

 Max. inlet pressure
 Max. outlet pressure

    

 Body

  

   Diaphragm

Hastelloy C 276

 Flow rate

 Materials

 Weight 

 Outlet pressure connection

 Inlet pressure connection

¼ - 18 NPT inside

2,1 kg

SS 316 L

DIN 477, acc. to gas type (other connections on request)

1.3 Technical data

     Cone or seat sealing

25 bar max.

0,05 - 1,5 bar (higher pressures on request)

acc. to type 0,03 - 20 m³/h, in standard conditions

PCTFE

FE 121

118

ca. 115

100

59

122

1/4”- 18 NPT

P

H

P

V

1/4”- 18 NPT

!

7. Repair

7.1 Repairs may only be carried out 

by expert

 

persons.

7.2 Only original spare parts must be used. The materials have been adapted to the

 

gas type in each instance. So always specifiy the gas type

7.3 In case of independent repairs, the use of non-original spare parts or changes on 

the side of the user or a third party without the approval of the manufacturer, 
any form of liability for resulting damages will expire as well as the 
manufacturers warranty.

7.4 After being repaired, the pressure regulator must be checked with respect to  
 

proper function, leak-tightness and cleanliness of the gas-wetted surfaces.When

 

the system is used again, a sufficient purging operation must be carried out first.

in authorized repair workshops 

R

spectrocem

Instructions for use

FE 121

Pressure regulator for special gases

GES_FE121_Edition 0211