Spectra Precision Focus 6 5" Total Station User Guide
195
Error Messages
10
NO Stn Setup
100.27
You did not perform a station setup or BS check before entering the Stakeout function.
B
Tip –
Selecting
Continue
does
not
resume the last ST record. You should only use the
Continue
option if you are sure that the previous ST coordinates and the current HA
orientation are correct. Otherwise, records in the Stakeout function may not be correct.
Station Setup
Calc ST Failed Need additional PT
100.28
Calculating ST failed in resection. This message may appear after you have deleted a
point the View shots screen.
Press any key to return to the PT input screen. Take another shot to calculate the ST
coordinate.
Same Coordinate
100.29
The input PT or coordinate is identical to the current station in STN/1:Known, or the
same coordinate or point name/number is found in Resection.
Press any key to return to the PT input screen. Then use a different PT.
Space LOW
100.30
There is not enough space to record a station when you start any of the Station Setup
functions.
XY-coordinate is required
100.31
The input point for ST/BS does not have N/E coordinates.
Press any key to return to the PT input screen. Then use a PT that has N/E coordinates.
Z-coordinate is required
100.32
The input point for Benchmark does not have a Z coordinate.
Press any key to return to the PT input screen. Then use a PT that has a Z coordinate.
To...
Press ...
go to the Stn Setup menu
[2]
or select
Stn Setup
return to the Basic
Measurement Screen (BMS)
[ESC]
go to the Stakeout menu
[1]
or select
Continue
To ...
Press ...
return to the BMS
press
[ESC]
or the
Abrt
softkey. Use the
DEL
softkey in Job Manager to delete old jobs.
continue
press
[ENT]
or the
OK
softkey. You may not be able
to record the whole process.
Summary of Contents for Focus 6
Page 1: ...Spectra preciSion 6 5 TOTAL STATION...
Page 2: ...Blank page Inside cover...
Page 3: ...Version 1 00 Revision A October 2009 User Guide Spectra Precision Focus 6 5 Total Station...
Page 6: ...4 Spectra Precision Focus 6 5 Total Station User Guide...
Page 12: ...Safety 10 Spectra Precision Focus 6 5 Total Station User Guide...
Page 24: ...1 Introduction 22 Spectra Precision Focus 6 5 Total Station User Guide...
Page 112: ...4 Applications 110 Spectra Precision Focus 6 5 Total Station User Guide...
Page 170: ...7 Specifications 168 Spectra Precision Focus 6 5 Total Station User Guide...
Page 174: ...8 System Diagrams 172 Spectra Precision Focus 6 5 Total Station User Guide...
Page 190: ...9 Communications 188 Spectra Precision Focus 6 5 Total Station User Guide...