Spectra 20K/64K Library AIT-4 Drive Upgrade

3

Updating Firmware Using the LC

1.

On the Library Controller, select 

Toolbars

, then select 

Maintenance

. The 

Maintenance toolbar displays.

2.

Select 

Update F/W

. The Firmware Update screen displays (Figure 1).

3.

In File Locations, select 

Local Directory -> Select Location

, then select the 

most recent firmware package. 

4.

Select 

Update Firmware

. The library firmware update process begins. A window 

displays a message, asking you to wait.

Caution:

Do not interrupt the library while firmware is downloading. The 

firmware download takes less than 10 minutes.

Figure 1  

Firmware Update screen.

Summary of Contents for AIT-4

Page 1: ...ns on page 6 Preparation 1 Identify the drives to be upgraded in your Spectra 20K 64K library 2 Make sure you have an AIT 4 drive for every drive you are replacing and a library firmware upgrade diske...

Page 2: ...LCM 3 Follow on screen directions inserting disks one at a time until operation is complete 4 Remove all disks and reset the LCM The operating system and Library Controller will now be upgraded 5 The...

Page 3: ...rmware Update screen displays Figure 1 3 In File Locations select Local Directory Select Location then select the most recent firmware package 4 Select Update Firmware The library firmware update proc...

Page 4: ...want to replace the select Replace A dialog box series displays first asking whether it is Okay to Replace Drive then Are you sure you want to open the door 4 Select Okay for each This powers down th...

Page 5: ...ller then select OK The library processes this change and may require a few minutes to complete When the drive has been configured another statement displays The library geometry has changed Reloading...

Page 6: ...ed data and run a restored program Refer to your backup software documentation for a more specific procedure After you have performed a drive test successfully continue 2 Restart backup processes Sony...

Page 7: ...ary depends on the number of drives installed in the library c The sustained transfer rate can increase by an average of 2 6 times with compression dependent on the type of data 3 MB sec native 6 MB s...

Page 8: ...Spectra 20K 64K Library AIT 4 Drive Upgrade 8...

Reviews: