Intelligent Analytics
NVR User Manual
76
11
General Event Management
11.1 Sensor Alarm
To complete the entire sensor alarm settings, you should enable the sensor alarm of each camera and then set up the alarm handling of each camera.
①
Click Start
Settings
Alarm
Sensor to go to the following interface.
②
Select the alarm type (NO or NC) according to trigger type of the sensor.
③
Enable the sensor alarm of each camera and select the schedule.
④
Check the “Duration”, “Record”, “Snapshot”, “Push”, “Alarm-out” and “Preset” and enable or disable the “Buzzer”, “Pop-up Video”, “Pop-up
Message Box” and “E-mail” as required.
⑤
Click “Apply” to save the settings.
The configuration steps of the above mentioned alarm linkages are as follows.
Duration: it refers to the interval time between the adjacent motion detections. For instance, if the duration time is set to 10 seconds, once the
system detects a motion, it will go to alarm and would not detect any other motion (specific to camera) in 10 seconds. If there is another motion
detected during this period, it will be considered as continuous movement; otherwise it will be considered as a single motion.
Record: check it and then the “Trigger Record” window will pop up automatically (you can also click the “Configure” button to pop up the window).
Select camera on the left side and then click
to set the camera as the trigger camera. Select trigger camera on the right side and then click
to cancel the trigger camera. Click “OK” to save the settings. The trigger cameras will record automatically when the sensor alarm is triggered.
Snapshot: check it and then the “Trigger Snapshot” window will pop up automatically. Configure the trigger camera in the window. The trigger
cameras will capture images automatically when the sensor alarm is triggered.
Push: check it and choose ON or OFF. If it is ON, the system will send messages when the sensor alarm is triggered.
Alarm-out: check it and then the “Trigger Alarm-out” window will pop up automatically. Configure the trigger alarm-out in the window. The system
will trigger the alarm-out automatically when the sensor alarm is triggered. You need to set the delay time and the schedule of the alarm outputs.
See 11.6.1 Alarm-out for details.
Preset: check it and then the “Trigger Preset” window will pop up automatically. Configure the trigger preset of each camera. To add presets, please
see 6.2 Preset Setting for details.
Buzzer: if enabled, the system will begin to buzz when the sensor alarm is triggered. To set the delay time of the buzzer, please see 11.6.4 Buzzer for
details.