Shaft seal
▪
Single mechanical seals to EN 12756
▪
Shaft equipped with replaceable shaft protecting sleeve in the shaft seal area
Drive
Table 6: General motor data
Characteristic
Description
Design
Surface-cooled three-phase, low-voltage motor to IEC
Winding
50 Hz
Up to 2.2 kW: 230 V/ 400 V
3 kW and higher: 400 V/ 690 V
60 Hz
Up to 2.6 kW: 460 V
3.6 kW and higher: 460 V
Type of construction
IM V1
Enclosure
IP55
Mode of operation
Continuous operation S1
Thermal class
F with temperature sensors: 3 thermistors
4.5 Configuration and function
1
2
3
4
5
6
7
8
9
10
11
Fig. 4: Sectional drawing
1
Clearance gap
2
Discharge nozzle of the pump
casing
3
Casing cover
4
Shaft
5
Motor housing
6
Suction nozzle of the pump casing
7
Impeller
8
Shaft seal
9
Drive lantern
10
Pre-filter casing
11
Suction strainer
Design