background image

 
Polarizer Rotator 3” x 2” Slide Mount  
For Benchmark®/GS12000 Series 
Polarizers  

User Manual 

 
 

 

 
 
 

2I-12500-6 

Summary of Contents for GS12000 Series

Page 1: ...Polarizer Rotator 3 x 2 Slide Mount For Benchmark GS12000 Series Polarizers User Manual 2I 12500 6...

Page 2: ......

Page 3: ...Polarizer Rotator 3 x 2 Slide Mount For Benchmark GS12000 Series Polarizers User Manual 2I 12500 6...

Page 4: ...MOUNT 5 FITTING A GS12000 SERIES POLARIZER INTO THE POLARIZER ROTATOR 3 X 2 SLIDE MOUNT P N GS12500 7 ROTATING THE GS12000 SERIES POLARIZER 10 GENERAL CAUTIONS AND CARE OF THE POLARIZER 10 4 LEGEND B...

Page 5: ...rizer can then be rotated to present a specific plane of polarized light for sample analysis In addition to the 3 x 2 slide mounting plate on the P N GS12500 rotator mount there are slot grooves on ei...

Page 6: ...ck that the following items have been supplied A GS12500 polarizer rotator 3 x 2 slide mount in a Styrofoam box If ordered as P N GS12500 A GS12000 Series polarizer of your choice and a polarizer rota...

Page 7: ...2500 In operation as shown from the front side view Fig 1 a GS12000 Series polarizer is placed into the aperture opening 2 using the spring clip ring mount of the GS12000 Series polarizer to obtain a...

Page 8: ...of the rotator mount 1 that can be used to align to any of the angle marks on the graduated wheel 3 for reading if required Note The angle reading from alignment of a graduated mark on the wheel 3 wit...

Page 9: ...e mount 1 From Fig 3 the GS12000 Series Polarizer is to be positioned within the aperture 2 of the rotatable mount 1 with the knurled surface side of the spring clip ring mount of the polarizer facing...

Page 10: ...tab on the spring clip ring mount of the polarizer may need to be bent slightly outwards away from the centre of the polarizer This movement will very slightly alter the overall circumference of the...

Page 11: ...ce See Fig 4 When the polarizer is installed in this position in the aperture 2 the lines of parallelism of the polarizer grid are running from the 12 O clock to the 6 O clock position of the polarize...

Page 12: ...inium lines being deposited on a substrate material and they can very easily be damaged due to incorrect handling of the polarizer There is a certain level of protection of the GS12000 Series polarize...

Page 13: ...e mount runners on rear plate of rotator mount 8 Securing screw for 3 x 2 slide mounted Accessory 5 Spare Parts Polarizer Rotator 3 x 2 Slide Mount and Kits GS12500 Benchmark polarizer rotator 3 x 2 s...

Page 14: ...User Manual 12 Notes for GS12000 Series Polarizer Use...

Page 15: ...bsite www systems eng co jp Spain Teknokroma S Coop C Ltda Barcelona Tel 93 674 8800 Fax 93 675 2405 email comercial teknokroma es Switzerland Portmann InstrumentsAG Biel Benken Tel 061 726 6555 Fax 0...

Page 16: ...SPECAC INC 414 Commerce Drive Suite 175 Fort Washington PA 19034 USA Tel 215 793 4044 Fax 215 793 4011 SPECAC LTD River House 97 Cray Avenue Orpington Kent BR5 4HE Tel 44 0 1689 873134 Fax 44 0 1689...