Speakman SF-9100 Instructions Manual Download Page 1

INSTRUCTIONS FOR MODELS

92-SF-9100-02

For additional assistance or service please contact:

SPEAKMAN

®

800-537-2107

[email protected]

www.speakman.com

SF-9100
SF-9200

HELPFUL TOOLS & SUPPLIES:

TOOLS AND SUPPLIES

Adjustable

Wrench

Phillips

Screwdriver

Pencil

Aerator

Wrench

(included)

Mounting

Hardware

(not included)

Drill

3/8"

Wrench

Safety

Glasses

Warranty information can be found at: 
www.speakman.com

WARRANTY

MAINTENANCE

Cover your drain to prevent loss of parts. Be sure to 
wear eye protection while cutting pipe.

SAFETY TIPS

IMPORTANT

• Be sure to read instructions thoroughly before  
   beginning installation.

• Do not over-tighten any connections or damage  
   may occur.

• This faucet has an operating range of 20-80 psi.

Your new Speakman Product is designed for years of 
trouble-free performance. Keep it looking new by 
cleaning it periodically with a soft cloth. The use of harsh 
chemicals and abrasives may damage the finish and 
void the product warranty. Please be sure to only use 
approved cleaners. Please contact Speakman for any 
clarification of acceptable cleaners.

1

Verify that the Rubber Gasket is in position and 
aligned to the base of the Faucet.

2

Place Hose and Sensor Wire carefully, one at a 
time, thru hole in mounting surface. Lower Faucet 
into position.

3

From below, install Rubber Washer (1), Metal 
Washer (2), and secure with Mounting Nuts (3). 
Align Faucet to desired position and wrench 
tighten Mounting Nuts (3).

OR

4

Assemble the Solenoid "OUTLET" Hose of the 
Faucet (1) to the "OUTLET" connection (2) of 
Solenoid. Wrench tighten.

DRY CONNECTION ONLY.

DO NOT USE ANY SEALANT 

ON THIS CONNECTION

5

Place the Solenoid Assembly against the desired mounting surface while ensuring adequate clearance for 
servicing of all connections. If using the optional A/C Adapter, consider the distance to the nearest electrical 
outlet. Solenoid Assembly should be mounted so the inlet and outlet ports are aligned vertically. Mark location 
of Solenoid Assembly on the mounting surface using a pencil.

10-7/8”

(275mm)

MAX

LEFT OR RIGHT

OF CENTER

9-7/16”

(240mm)

MAX

6

Remove Mounting Bracket (1) from Solenoid Assembly. Using the previously marked location on mounting 
surface, align Mounting Bracket (1) horizontally to approximate position and mark the mounting locations with a 
pencil. If mounting on drywall and not to stud, use the appropriate anchors and fasteners for application. 
Recommend screw in easy anchor or equal for drywall.

IMPORTANT NOTE

Verify that all hoses are free from bends or kinks.

7

After securing the Bracket to the mounting surface, align and slide Solenoid Assembly over Mounting Bracket.

8

Assemble "INLET" Supply Hose (1) (not supplied), 
to the "INLET" connection (2) of Solenoid. 
Wrench tighten.

DRY CONNECTION ONLY.

DO NOT USE ANY SEALANT 

ON THIS CONNECTION

9

Make electrical connections from the Sensor
Eye to the Solenoid Assembly. Connect the Blue 
Male Ended Wire to the Blue Female Connection. 
Connect the Green Male Ended Wire to the 
Green Female Connection. To further aid proper 
alignment, there are white alignment lines on the 
connector ends. These alignment lines should 
face forward when properly installed.

GREEN

BLUE

Summary of Contents for SF-9100

Page 1: ...se of the Faucet 1 to the OUTLET connection 2 of Solenoid Wrench tighten DRY CONNECTION ONLY DO NOT USE ANY SEALANT ON THIS CONNECTION 5 Place the Solenoid Assembly against the desired mounting surfac...

Page 2: ...w to be functioning If the Faucet activates but the water will not shut off 1 Hold a hand in front of the Sensor at up to 7 away for more than 1 minute until the water flow stops Once the water stops...

Page 3: ...ccordance with the highest quality and performance standards With proper care it will provide years of hygienic and trouble free service 2 Periodically the Faucet will require some minor maintenance t...

Page 4: ...e appropriate hole in the counter top one at a time Align the valve assembly so the Rubber Access Plug 1 is facing the rear and install Valve Assembly through mounting hole 3 From below reinstall the...

Page 5: ...N INCHES MILLIMETERS UNLESS OTHERWISE SPECIFIED DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE 2 MIN TO LEDGE 51mm 2 MIN TO WALL 51mm LAVATORY ROUGH IN 29mm 1 1 8 MIN NOTES COMPLIANCE CONNECTIONS ASME A1...

Page 6: ...until the bracket is flush to the wall surface Secure the Plastic Wall Bracket to the wall with the proper Mounting Screw included 5 16 OR OR 3 Ensure the A TMV is vertical and the body rests on the...

Page 7: ...e Element s body Note Gallon per minute ratings may vary depending upon incoming water temperatures and pressures Hot and cold water inlet pressures must be equal Provisions shall be made to thermally...