SpeakerCraft SmartPath IRE-1.0 Installation Instructions Manual Download Page 1

DESCRIPTION

The IRE-1.0 represents the highest level in sophistication for attachable
IR Emitters. It features a unique EZ-Docker

port that permits instant

removal of the emitter when rearranging or servicing components.
An improved adhesive reduces callbacks for reattachment of “fallen
emitters”. The case may also be taken apart so that the tiny internal
emitter can be placed inside a component, when desired. High IR
output from the top curved surface allows emitter to be mounted on
a nearby surface, below, above or on a cabinet door, rather than
directly on the sensor of the unit where conditions
permit.

ATTACHMENT

First, locate the component’s IR sensor window 

(see Note 1)

and

thoroughly clean it of any fingerprints or other greasy substances. 
The EZ-Docker

port has a clear adhesive layer on its bottom surface.

Peel the protective layer off,
exposing the adhesive. 

Orient the port vertical 

(see

Fig. 2)

and press it over the

center of the component’s
sensor window. Press and
hold for several seconds to
ensure maximum contact
of the adhesive.

Slide the emitter from the
top down, into the EZ-
Docker

port. You should

feel it “snap” into place. (To
remove the emitter at any
time, simply push upward
until it “pops” out). 

IRE-1.0

Emitter

 

8 FT

9/16"

7/16"

3.5mm 

mini plug

1/4"

Side View

Emitter

Wire Lead

Docking

Port

Clear Adhesive Tape

(See Note 3)

Top View

NOTE: White striped side is positive ( +)

(– )

(+)

Emitter slides into 
Docking Port

Fig. 1

Insert the 3.5mm plug into an Emitter jack on a SpeakerCraft
Terminator or other source of IR 

(see Fig. 3)

.

CAUTION:

Do not plug into an emitter jack that is set to Blaster

Power (BL ON) or to the HIGH OUT of other connecting blocks.

To do so will smoke the emitters!!

Note 1:

If you have difficulty finding the component’s IR sensor, try

using a flashlight. Sometimes the owner’s manual is helpful. You may
need to contact the manufacturer direct. 

Note 2:

You may also attach the emitter without the EZ-Docker

port.

Use one of the spare adhesives (included) applying it directly to the
bottom surface of the IRE-1.0 shell.

Note 3:

If you need to remove the EZ-Docker

port or emitter previ-

ously stuck to a component’s surface, use a fresh adhesive (included)
before reattaching.

Note 4:

The emitter shell and EZ-Docker

port, though dark in

appearance, are transparent to Infrared. This allows IR commands to
pass through them, permitting local hand held remote control as
well as through the IRE-1.0.

IR Controlled Components

IR sensor
window

Docking Port

IRE-1.0

 attached to

IR sensor window

2) Slide 

IRE-1.0

 Emitter

    end into docking port

1) Attach 

IRE-1.0

 Docking Port

    to IR sensor window with adhesive pad

Fig. 2

IRE-1.0

IR Emitter

Sp

e

a

k

e

rC

ra

ft

SmartPath

INSTALLATION INSTRUCTIONS

LIT03100  02/02

ELT03100

®

Reviews: