Spark modern fires FT108-N Owner'S Operation And Installation Manual Download Page 1

Version française de ce manuel est disponible à partir du site WEB : www.sparkfires.com

French version of this Owners Manual is available at www.sparkfires.com

WARNING

flammable vapors and liquids in the

Do not store or use gasoline or other

vicinity of this or any other ap

p

liance.

WARNING

Read the installation, operating and maintenance

instructions thoroughly before installing or servicing

this equipment.

Improper installation, adjustment, alteration, service, 

or maintenance can cause injury or property damage.

DANGER

CARBON MONOXIDE HAZARD

This  appliance  can  produce

carbon 

     

monoxide 

    

which

has no odor. 

   

Using it in an

enclosed space can kill you.

 

Never 

  

use

  

 this 

   

appliance 

in

   

an 

 

enclosed space 

 

as a 

camper, tent, 

 

car

  

or

 

 home

.

DANGER

If you smell gas:
1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the

appliance and immediately call your
gas supplier or fire department.

WARNING:

 

For Outdoor Use Only

INSTALLER: 

Leave this manual with the appliance.  CONSUMER: Retain this manual for future reference.

IMPORTANT: Outdoor fireplaces should not be installed in areas susceptible to saltwater corrosion or high winds.

These products are not warranted against either condition.

  

 

C

S

A 2.17-20

17

 "Gas

-

Fired Appliances for Use at High Altitudes"

                    

 

ANS Z21.97

.

CSA 2.41-201

7

  "Outdoor Decorative Gas Appliances",

 

Complies with

A

 propane 

cylinder not connected for 

use

 

shall not be stored in the vicinity 

of this

 

or any other ap

p

liance.

R

eport 

0321GF007S

OUTDOOR FIRE TABLE

Summary of Contents for FT108-N

Page 1: ...ou Never use this appliance in an enclosed space as a camper tent car or home DANGER If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues keep away from the app...

Page 2: ...on or near the appliance 6 Clothing or other flammable high surface temperatures and should stay away to avoid burns or clothing ignition trical Code ANSI NFPA 70 or the Canadian Electrical Code CSA...

Page 3: ...iance is used shall comply with one of the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that inclu...

Page 4: ...before proceeding to the next step the parts in accordance with these diagrams or failure to use only parts specially approved with this appliance may result in property the metal data plates Burner...

Page 5: ...lustrated Parts List page 15 must be in place when appliance is not in use Firetable Dimensions Firetable can be installed on any non combustible materials FT36 N P FT48 N P FT60 N P FT72 N P FT84 N P...

Page 6: ...off the gas to the appliance Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male NPT threads This will...

Page 7: ...er immediately 2 To ease installation a 30 mm flex line with manual shut off valve has been provided with on this appliance Install and attach 1 2 gas line onto shut off valve Outlet Pressure Tap Pilo...

Page 8: ...TUBE N G Prop MEDIA BURNER TRAY PILOT BURNER TUBE 10 3 4 25 6 7 1 5 OVERAL WIDTH W TOP COVER DIMENSIONS TOP COVER WELD ON HANDLE TOP COVER WIDTH W 0 65 4 1 2 5 17 5 4 16 FT36 N P 24 20 41 000 33 500...

Page 9: ...D BEFORE OPERATING LIGHTING FOR THE FIRST TIME INITIAL LIGHTING Purge air from the supply line as follows Open main shutoff valve Unscrew main pressure test point Leave inlet test screw open until gas...

Page 10: ...o light the pilot by hand If you don t smell gas go to the next step WARNING 7 Turn the gas control manual valve to the ON position 8 Plug supplied 7V DC adapter into 110V power outlet LIGHTING FOR TH...

Page 11: ...lectrical power supply or performing service All wiring shall be in compliance with all local city and state codes The appliance when installed must be electrically grounded in accordance with local c...

Page 12: ...operation The pilot flame must always be present when the fireplace is in operation or connected to the gas line with main shutoff valve open and the IPS activated powered The pilot flame has two dis...

Page 13: ...ts to produce moderate levels of carbon soot where flames Burner is excessively noisy Note The movement and combustion of gas will create low unavoidable levels of noise Burner flame is too low or too...

Page 14: ...leads disconnected 1 Pilot flame needs adjusting 1 Gas leak See Warning statement above 1 Gas leak See Warning statement above IMPORTANT Operating unit where impurities in air exist may create odors C...

Page 15: ...FOR PART DESCRIPTION SEE NEXT PAGE 16 ILLUSTRATED PARTS LIST 15 16 18 15 14 1 8 5 2 3 4 6 7 9 10 11 12 13 17 19...

Page 16: ...120207 W120208 R100027 R100027 R100027 R100027 R100027 3 Pilot Assembly R100028 R100028 R100028 R100028 R100028 1 R100029 R100029 R100029 R100029 D300098 D300098 D300098 D300098 1 5 DFC Wire Assembly...

Page 17: ...5 1 14 DFC Board H100142 H100142 H100142 H100142 H100142 1 15 Remote Receiver RCB R RCB R RCB R RCB R RCB R RCB R RCB R 1 17 6 Volt Battery Pack H100139 H100139 H100139 H100139 H100139 1 18 7V 10mA DC...

Page 18: ...17 Pilot Assembly 6 Volt Battery Backup uses 4 pcs AA Batteries...

Page 19: ...ance Inside Corner Trees Shrubs Other Termination Please Describe Prevalent Wind Conditions Other Installation Notes The installer should complete the form below that describes the details of the inst...

Page 20: ...and does not extend to 1 firebox burner assembly damaged by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of r...

Reviews: