background image

 

 

 
 
 
 
 
 
 
 

 

 
 
 

C

OLD 

T

RAP 

O

PERATOR

M

ANUAL

 

 

 

FTS

 

S

YSTEMS 

T

ITAN

-T

RAP

™ 

R

EFRIGERATED 

C

OLD 

T

RAP

 

 
 

 

Summary of Contents for FTS SYSTEMS TITAN-TRAP

Page 1: ...COLD TRAP OPERATOR S MANUAL FTS SYSTEMS TITAN TRAP REFRIGERATED COLD TRAP...

Page 2: ......

Page 3: ...anual by any means and in any form or manner is expressly prohibited except with the prior written permission of SP Scientific Permitted copies of this document must retain all proprietary notices con...

Page 4: ...RE FLAMMABLE MATERIALS IN CHAMBER PRACTICAL OPERATING TIP THESE RECOMMENDATIONS STREAMLINE UNIT OPERATION AND PREVENT COMMON OPERATOR ERRORS WEAR SAFETY GLASSES EXPLOSIVE MATERIALS HAZARD KEEP OBJECTS...

Page 5: ...repair of parts pursuant to this warranty shall not in any way extend the original warranty period The Company shall not be responsible for any unauthorized repairs replacements or product modificatio...

Page 6: ...iv Rev 007 04 12 SP Scientific 2012...

Page 7: ...spection 3 Setup 4 Service Connections 4 Vacuum Pump Installation 4 Titan Trap Installation 4 Vacuum Filters 6 Operation 7 Overview 7 Operating Instructions 7 Maintenance 9 Overview 9 Vacuum System 9...

Page 8: ...Contents FTS Systems Titan Trap vi Rev 007 04 12 SP Scientific 2012...

Page 9: ...ytetrafluoroethylene PTFE coated condenser chamber is available in both 4 and 8 liter capacities Key Features Extremely compact design Several CFC free refrigeration options with temperatures as low a...

Page 10: ...Introduction FTS Systems Titan Trap 2 Rev 007 04 12 SP Scientific 2012...

Page 11: ...ately 1 Keep all contents packing material and related paperwork intact until a written report is obtained Note SP Scientific will cooperate in the matter of collecting your claim but is not responsib...

Page 12: ...according to local state and or national electric codes Vacuum Pump Installation A remotely mounted vacuum pump sold separately is required for operation The vacuum pump should not exceed 250 liters m...

Page 13: ...Apply a thin coating of vacuum grease to the gasket on top of the Titan Trap 8 if necessary and install the glass dome into the gasket Plug the vacuum pump into the standard receptacle marked VACUUM P...

Page 14: ...austed by the vacuum pump If an OME is not available vent the vacuum exhaust externally Additionally vacuum filter traps are available for installation between the vacuum pump and the Titan Trap unit...

Page 15: ...D will illuminate immediately signifying that the refrigeration system has begun cooling the condenser coil If your unit is equipped with a cascade refrigeration system the Cool indicator LED will not...

Page 16: ...position and allow the condensate to melt and drain Defrosting may be expedited by adding hot water to the trap Close the drain valve remove the glass dome and add water directly to the condenser cham...

Page 17: ...IALS OR ORGANIC SOLVENTS OIL MUST BE CHECKED AND CHANGED MORE OFTEN IN ADDITION A FILTER TRAP MAY BE INSTALLED TO PROTECT THE VACUUM PUMP Clean oil is necessary for the best vacuum and overall efficie...

Page 18: ...n check the oil after the test cycle If the oil appears dirty change the oil after every use If the used oil appears clean change the oil after the next two uses or cycles If the oil remains clean aft...

Page 19: ...nser into the ambient air Reduced airflow over the condenser can result in severely reduced performance and may shorten the life of the compressor To maintain the air cooled condenser and compressor R...

Page 20: ...hours at room temperature This will allow the internal pressures to equalize The shroud will need to be removed to allow the Hi and Lo side access valves to be visible If the actual system pressure m...

Page 21: ...ump causing poor vacuum Typically if you get a vacuum reading below 500 millitorr on the controller or a vacuum gauge within 10 to 20 minutes you can rule out any problem with the pump vacuum probe an...

Page 22: ...Appendix A Troubleshooting FTS Systems Titan Trap 14 Rev 007 04 12 SP Scientific 2012...

Page 23: ......

Page 24: ...SP Scientific 815 State Route 208 Gardiner NY 12525 USA 3538 Main Street Stone Ridge NY 12484 www SPScientific com 800 431 8232 845 255 5000...

Reviews: