SOYAL
ACCESS CONTROL SYSTEM
®
Feature
Installation
Specification
Wires
Electric Bolt Lock
LK1201A/P(-3) Fail Safe/Fail Secure
The electric bolt lock, AR-1201A(-3) Fail Safe and "AR-1201P(-3) Fail Secure, featured with aluminum
alloy housing is able to dissipate the heat effectively. It supports door status sensor and bolt position
sensor functions. When the bolt is pried, it will send out alarm signal. One LED indicator will show the bolt
position (Red: Unlocked / Green: Locked / Yellow Flashing: Bolt was damaged or pried)
1. Please note the distance between the lock body and striker plate should NOT over 8mm; otherwise,
the bolt might not drop properly.
2. Installation Diagram (Please refer to the next page)
3. Operation delay time: 0 / 3 / 6 / 9 sec. (Default: 3 sec.)
Voltage
Optional
12VDC 24VDC
Current Draw
AR-1201A(-3)
Fail Safe
Switch on 900mA 500mA
Normal on 350mA 180mA
AR-1201P(-3)
Fail Secure
Switch on 700mA 500mA
Normal on 170mA 180mA
Operating Temp. 0~50
℃
Door Opened
by
Black Wire (Controller) and Yellow Wire
(Lock Exist PB)
Indicator
Bi-Color LED
Face
Plate
(mm)
AR-1201A/P
Fail Safe/Secure
205L x 32W x 43H
AR-1201A/P-3
Fail Secure/Secure
200L x 32W x 43H
Striker
Plate
(mm)
AR-1201A/P
Fail Safe/Secure
104L x 25.5W x 5H
AR-1201A/P-3
Fail Secure/Secure
Bolt (mm) 16 (Diameter) x 16 (Throw)
1 2
9
Sec
1 2
6 Sec
1 2
3 Sec
1 2
0 Sec
Troubleshooting
1. After “Fail to lock”, the bolt will enter into “Keep locking” mode and re-lock twice every 5 seconds.
Users can push the door in the right position, and the bolt will automatically extend and locked.
2. Please check V(+) and V(-) wiring when LED doesn’t light up.
3. If the bolt projects but chatters, please check whether the power supply is less than 1000mA
(Voltage
too low.)
Bolt Status
LED Indicator
1201A(-3) Status 1201P(-3) Status
Door
Lock
Door
Lock
Stand-by (Power to lock) LED lights up Red
Off
Off
Off
Off
Delay Time Action
LED flashes Red once every 0.5 sec
On
Off
On
Off
Locked Well
LED lights up Green
On
Off
N/A
N/A
Fail to Lock
LED flashes Red once every 0.5 sec
On
Off
N/A
N/A
Keep Locking
LED flashes Red once every 0.5 sec
On
On
N/A
N/A
Forced Entry (Alarm)
LED flashes Yellow once every 0.5 sec
On
On
N/A
N/A
Remote Release (Exit PB) LED lights up Red
Off
Off
N/A
N/A
Red
Black
Yellow
Blue
White
Gray
Orange
Green
+12V or +24V
0V
PB
COM
N.O.
N.C.
N.O.
N.C.
V+
V- (CTL N.C.)
Exit PB
Door Status
Door Sensor
Alarm Input
GND
Bolt Status