Electric Bolt Lock

LK1201A/P(-3)  Fail Safe/Fail Secure

The electric bolt lock, AR-1201A(-3) Fail Safe and "AR-1201P(-3) Fail Secure, featured with aluminum 

alloy housing is able to dissipate the heat effectively. It supports door status sensor and bolt position 

sensor functions. When the bolt is pried, it will send out alarm signal. One LED indicator will show the bolt 

position (Red: Unlocked / Green: Locked / Yellow Flashing: Bolt was damaged or pried)

1. Please note the distance between the lock body and striker plate should NOT over 8mm; otherwise,

the bolt might not drop properly.

2. Installation Diagram (Please refer to the next page)

3. Operation delay time: 0 / 3 / 6 / 9 sec. (Default: 3 sec.)

Voltage

Optional

12VDC 24VDC

Current Draw

AR-1201A(-3)

Fail Safe

Switch on 900mA 500mA
Normal on 350mA 180mA

AR-1201P(-3)

Fail Secure

Switch on 700mA 500mA

Normal on 170mA 180mA

Operating Temp. 0~50

Door Opened 

by

Black Wire (Controller) and Yellow Wire 

(Lock Exist PB)

Indicator

Bi-Color LED

Face 

Plate

(mm)

AR-1201A/P

Fail Safe/Secure

205L x 32W x 43H

AR-1201A/P-3

Fail Secure/Secure

200L x 32W x 43H

Striker

Plate

(mm)

AR-1201A/P

Fail Safe/Secure

104L x 25.5W x 5H

AR-1201A/P-3

Fail Secure/Secure

Bolt (mm) 16 (Diameter) x 16 (Throw)

1    2

9

 

Sec

1    2

6 Sec

1    2

3 Sec

1    2

0 Sec

Troubleshooting

1. After “Fail to lock”, the bolt will enter into “Keep locking” mode and re-lock twice every 5 seconds.

     Users can push the door in the right position, and the bolt will automatically extend and locked.

2. Please check V(+) and V(-) wiring when LED doesn’t light up.

3. If the bolt projects but chatters, please check whether the power supply is less than 1000mA

(Voltage 

too low.)

Bolt Status

LED Indicator

1201A(-3) Status 1201P(-3) Status

Door

Lock

Door

Lock

Stand-by (Power to lock) LED lights up Red

Off

Off

Off

Off

Delay Time Action

LED flashes Red once every 0.5 sec

On

Off

On

Off

Locked Well

LED lights up Green

On

Off

N/A

N/A

Fail to Lock

LED flashes Red once every 0.5 sec

On

Off

N/A

N/A

Keep Locking

LED flashes Red once every 0.5 sec

On

On

N/A

N/A

Forced Entry (Alarm)

LED flashes Yellow once every 0.5 sec

On

On

N/A

N/A

Remote Release (Exit PB) LED lights up Red

Off

Off

N/A

N/A

Red 

Black 

Yellow 

Blue 

White 

Gray

Orange 

Green 

+12V or +24V

0V

PB

COM

N.O.

N.C.

N.O.

N.C.

V+

V- (CTL N.C.)

Exit PB

Door Status

Door Sensor

Alarm Input

GND

Bolt Status

Reviews: