Soyal AR-881EF Instruction Manual Download Page 1

SOYAL

ACCESS CONTROL SYSTEM

®

AR-881EF/AR-881EV

V110221

   

     

AR-881EF

AR-881EV 

or

P1

P2

P3

P6

P4

P7

P5

   

P1

P2

P3

P4

P5

P6

P7

1

2

3

1

2

3

4

5

Contents

1

Product

2

User Guide

3

Terminal Cables

4

Tools

Protection Plug

Security Torx Wrenches

Flat Head Hex Socket 

Screw: M3x8

Flat Head Cap Philips
Tapping Screw: 4x38

Wire Application Wire

Color

Description

Lock Relay

1

Blue White (N.O.)DC24V1Amp

2 Purple White (N.C.)DC24V1Amp

Common-COM-Point

3

White

(COM)DC24V1Amp

Door Contact

4

Orange

Negative Trigger Input

Exit Switch

5

Purple

Negative Trigger Input

Alarm Relay

6

Gray

Transistor Output Max. 12V/100mA 

(Open Collector Active Low)

Power

7

Thick Red DC 12V

8

Thick Black DC 0V

P1

Cable:

Wire Application Wire

Color

Description

Anti-Tamper 

Switch

1

Red

N.C.

2

Orange

COM

3

Yellow

N.O.

P5

Cable:

Wire Application Wire

Color

Description

Power

1

Red

DC 12V Output

Security trigger signal  2

Purple

Security trigger signal Output

Arming

3

Red White Arming Output

Duress

4 Yellow White Duress Output

P6

Cable:

Wire Application Wire

Color

Description

1

---

---

2

---

---

TCP/IP Output

3 Orange White Net - RX-
4

Orange

Net - RX+

5 Green White Net - TX-
6

Gerrn

Net - TX+

7

---

---

P3

Cable:

Wire Application Wire

Color

Description

RS-485 for Lift

Controller

1 Thick Green RS-485(B-)
2

Thick Blue RS-485(A+)

P4

Cable:

Wire Application Wire

Color

Description

Beeper

1

Pink

Beeper Output 5V/100mA, Low

LED

2

Yellow

Red LED Output 5V/20mA, Max

3

Brown

Green LED Output 5V/20mA, Max

Door Output

4

Blue White Transistor Output Max. 12V/100mA 

(Open Collector Active Low)

Wiegand

5

Thin Green Wiegand DAT: 0 Input

6

Thin Blue Wiegand DAT: 1 Input

WG Door Contact 7

Orange

Negative Trigger Input

WG  Exit Switch

8

Purple

Negative Trigger Input

P2

Cable:

External WG keyboard

※ 

If you want to program system on controller directly, please order WG keyboard then install it according to the following pattern.

Remove the Protection plug that in the bottom left.
(

 Do not lose protection plug or it will affect the protection level.)

WG Keyboard cable will be connected to the pin board.
WG Keyboard connected to the controller from the bottom left of the hole.

When you finish programming system, please put protection plug back to the 

controller.

Installation

Connector Table

Wire Application Wire

Color

Description

Doorbell

1 Black White Transistor Output Max. 12V/100mA 

(Open Collector Active Low)

2

Black

GND

P7

Cable:

(For the controller that doorbell function.)

Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall. 
Connect the terminal cables to the body and attach the body to the mounting plate.
Assemble the covers with the Allen key and screws (accessories supplied). 
Turn on the power and LED will light and beep will sound.

※      

only provide to the controller that have doorbell function.

P7

Summary of Contents for AR-881EF

Page 1: ...or Description Beeper 1 Pink Beeper Output 5V 100mA Low LED 2 Yellow Red LED Output 5V 20mA Max 3 Brown Green LED Output 5V 20mA Max Door Output 4 Blue White Transistor Output Max 12V 100mA Open Colle...

Page 2: ...Wiring Diagram Electric Bolt Controller Controller Controller Controller Reader Controller Controller RTE RTE RTE RTE RTE POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER...

Page 3: ...or details e g If the AR 881EF EV set to exit reader WG Reader set to access reader Access programming mode 20 0 128 20 1 192 Please refer to function default value for details Enable Disable auto ope...

Page 4: ...ct valid card Input 4 digit arming code U Disable particular device Induct valid card Input 4 digit arming code U Input 5 digit user address Input 4 digit pass code Input 4 digits arming code or U Ind...

Page 5: ...in the SOYAL web to downloads Front Panel Indicator How to place finger for finger vein authentication unit Error Left button Right button OK Processing F1 Light Duty on F5 Flash Break out F2 Light Du...

Page 6: ...Address is the same as sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User P...

Page 7: ...settings 09 PPPPPPRRRRRR PPPPPP New master code RRRRRR Repeat the new master code Suspend or delete tags Suspend 10 SSSSS EEEEE Suspend Delete SSSSS starting user address EEEEE ending user address De...

Page 8: ...pacitive fingerprint recognition 012 Optical Capacitive fingerprint recognition Adding Deleting Fingerprint or Finger Vein 39 F UUUUU F 1 Adding one finger data 2 Adding two finger data 0 Delete UUUUU...

Reviews: